Descargar Imprimir esta página

Mi-T-M Corporation HG Serie Manual De Instrucciones página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

ATTIRE:
Proper attire is essential to your safety. It is advised to utilize whatever
means necessary to protect eyes, ears, and skin. Additional safety attire
(such as respiratory mask) may be required when using detergent cleaning
agents with this pressure washer.
DANGER RISK OF EXPLOSION OR FIRE! SMELL FOR GAS
BEFORE STARTING UNIT.
THE MACHINE FOR A GAS SMELL. BE SURE TO SNIFF FLOOR
AREA, SINCE SOME GAS IS HEAVIER THAN AIR AND WILL
SETTLE ON THE FLOOR.
IF YOU SMELL GAS:
• Do not start unit.
• Do not operate any electrical switch.
• Do not light any appliance.
• Do not use any phone in the room or area.
• Leave, go to another location and use a phone to call your gas sup-
plier.
• Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
PRE-START:
1. Before lighting, smell all around the machine for gas. Especially, sniff
the floor area because some gas is heavier than air and will settle on the
floor. Do not operate unit if smell exists. Leave the location and contact
a qualified serviceman.
2. Check to ensure the voltage is on.
3. Pump oil level should be checked before each use. Check the oil level
with the dipstick on top of the pump crankcase. (See illustration #10.) The
proper oil level should be at the notch on the dipstick. If the level appears
low, use pump oil SAE20 or 30 non-detergent.
UNLOADER:
The unloader has been preset at the factory and should only be adjusted by
a trained serviceman.
QUICK-CONNECT NOZZLES:
Various nozzles may be quick connected into the end of the adjustable pres-
sure dual lance to change the spray pattern or use the detergent feature.
When using Quick- connects (Q.C.), be certain the connection is securely
locked. (See illustration #11). If not, the high pressure water may shoot the
nozzle from the lance, causing severe injury or serious damage. To deter-
mine spray fan, (see illustration #12) refer to the actual number stamped on
the nozzle. The first two digits indicate the spray fan in degrees, i.e., 00=0°,
15=15°, 25=25°, 40=40°.
1. The 0° nozzle (RED): This is a blasting nozzle. It delivers a very concentrated
stream of water. Be cautious when using the straight narrow stream. It is
not recommended for use on painted or wood surfaces or items attached
with adhesive backings. Uses: Removing weeds from sidewalk cracks,
stubborn stains from concrete, masonry, aluminum and steel, caked mud
from equipment, and cleaning lawn mower undersides.
2. The 15° nozzle (YELLOW): This is a chiseling nozzle. The spray should be
directed at a 45° angle to the surface and used like a scraper to remove
paint, grease and dirt. Uses: Surface preparation (removing mildew stains
and paint chips).
3. The 25° nozzle (GREEN):
a. This is a flushing nozzle. This pattern is best suited for flushing dirt,
mud, and grime. Uses: Wet sweeping leaves from walk curbs and
Operator's Manual
PREPARATION
ALWAYS SNIFF AREA
AROUND
Illustration #10 Pump-rear oil gauge
15

Publicidad

loading

Este manual también es adecuado para:

Hg-3004-3460Hg-3004-1208Hg-3004-1230Hg-3004-3230Hg-3004-3208