en - Technical data
Voltage variants/electrical data
Voltage variant 1
Supply voltage
Frequency
Power rating
Fuse rating (on site)
Minimum cross-section for connection cable
Cable gland
Voltage variant 2
Supply voltage
Frequency
Power rating
Fuse rating (on site)
Minimum cross-section for connection cable
Cable gland
Exhaust air
Maximum nominal volume flow rate in extraction mode (PDR 9xx
only)
Maximum nominal volume flow rate (PDR 5xx only)
Maximum permitted pressure loss
Connector on machine side (external diameter)
Connection pipe provided on site (internal diameter)
Maximum exhaust air temperature
As relative humidity inside the exhaust ducting can be as high as 100 %, suitable measures must be taken to prevent a backflow of
condensate into the machine.
Air intake
Standard connection: air intake from installation site
Recommended free air intake cross-section into the room:
(equivalent to 3 times the exhaust air cross-section of a machine).
There must be sufficient air intake to the installation site to match the air outlet volume.
Alternative connection: air intake connection directly from outdoors
Connection sleeve on machine side (internal diameter)
Connection pipe provided on site (external diameter)
Removing the protective cover exposes live parts. For safety reasons, a pipe must be installed from the tumble dryer's central fresh air
intake (over a minimum length of 900 mm) and secured with 2 screws.
Equipotential bonding (optional)
Connection with male thread
Washers and nuts
Accessories for equipotential bonding are not supplied and need to be ordered separately.
20
Standard connection
3N AC 400 V
50/60 Hz
37.7 kW
3×63 A
5×16 mm²
M50
Standard connection
3 AC 230 V
50/60 Hz
37.7 kW
3×100 A
4×35 mm²
M63
1100 m³/h
1000 m³/h
260 Pa
150 mm
150 mm
80 °C
531 cm²
161 mm
160 mm
10×35 mm
M10