5. Editing the firing parameters
Operation in the PRESS mode
Step 1:
Select the program type.
The furnace offers several types of
programs:
–
press programs for Ivoclar Vivadent
materials
–
FPF Fully automatic press function for IPS e.max Press materials
–
20 free, individually adjustable press programs
Step 2:
Select the desired press program.
Step 3:
Select the investment ring size.
Select the desired investment ring size
(100 g / 200 g / 300 g). In the Ivoclar
Vivadent press programs, not all investment
ring sizes are available for each material.
Step 4:
Load the furnace and start the program.
Load the furnace with the preheated
investment ring and activate the program
by pressing the START key.
10
Editing press programs
Bitte EN
The Ivoclar Vivadent press programs are equipped ex factory with the
optimum parameters for Ivoclar Vivadent pressed ceramic materials. These
programs are write-protected and cannot be edited. Individual press
programs can be edited in the same way as the firing programs (see 4.1).
Bitte EN
Bitte EN
Bitte EN
Please see the Operating Instructions for more detailed
information.