Descargar Imprimir esta página

Fagor FI-30 Instrucciones Generales Para Instalación, Uso Y Mantenimiento página 10

Ocultar thumbs Ver también para FI-30:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1.1.- Installation diagrams
See Fig.1.
1.2.- Positioning
Level and adjust the height of the appliance. (Fig. 2)
1.3.- Water connection
To be done as shown in figures 3 and 4.
Dynamic pressure necessary during rinse: 2 - 4 Kg/cm
2
Kg/cm
, install an electrical pressure pump. (Fig.4).
When the water hardness level is above 10º dF, a water softener should be installed.
1.4.- Drainage
a) Fix the drainage hose as indicated in Fig.5.
b) Fit a siphon pipe to prevent bad smells.
1.5.- Technical specifications
Water
MODEL
inlet
pressure
FI - 30
FI - 48
FI - 48B
1.6.- Electrical connection
− For access to the connection strip (R), (Fig. 1 and Fig. 6), remove the cover (T) and the
rear panel (P). Fix the sheathed cable to (E) leaving enough cable to remove the electrical
panel from the front.
− Connect the strip as shown in figure 6.
− Fit a general switch (I) independent of the appliance with a distance between contacts
equal to or more than 3 mm.
− The machine must be earthed.
Voltage
220-240-1N~
380-415V-3N~
1.- INSTALLATION
Supply
Power (Kw)
voltage
H. element
Drum
Tub
2,8
2,8
MODEL
S. cable
FI - 30
2
FI - 48
2x2.5mm
FI - 48B
FI - 30
2
FI - 48
4x2.5 mm
FI - 48 B
2
. With mains pressures of less than 2
Square
Max
basket
absorb.
(mm)
3,45
500x500
3,52
Fuses
+ T
20 A
+ T
20 A
9
Cycle
Tub
duration
capacity
(l)
4' Reg.
25
120''
180''
Mains connection
Rinse
Net
water
weigh
cons (l)
(Kg)
54
2,7
59
60

Publicidad

loading

Este manual también es adecuado para:

Fi-48Fi-48b