Descargar Imprimir esta página

Eurocave VOV3 Modo De Empleo página 26

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
5 - INSTALLATION
1I. Connecting the nitrogen bottle
Choose the location of your nitrogen bottle and
remove the protective seal.
Take the appliance's hose, slide the securing ring
onto the hose and push it onto the outlet of the
pressure reducer.
- Open the nitrogen bottle, the pressure gauge on the right-hand side displays a pressure of approximately 200 bars when the
bottle is full.
- Turn the black knob in a clockwise direction until a pressure of 1 – 2 bars is displayed.
IMPORTANT: NEVER EXCEED THE PRESSURE OF 2 BARS/29 PSI
WHEN SETTING THE PRESSURE, PLEASE BE AWARE THAT THE MORE YOU SCREW
THE HANDLE, THE MORE THE PRESSURE INCREASES.
III. Commissioning the nitrogen supply
(Only for the VOV3 manual model)
Power up the appliance by plugging it in.
Before installing the wine bottles, check the operation of the solenoid valve by pressing and
holding down the nitrogen warning indicator push button.
The nitrogen is automatically activated as soon as a tap is used.
The nitrogen warning indicator should then go out.
If this does not happen, refer to chapter 7.
-6-
Screw the pressure reducer onto the bottle
using a wrench
Screw the ring onto the hose using a
screwdriver.

Publicidad

loading

Este manual también es adecuado para:

Vov3 electronic