EasyTeach philosophy
5 s
Adjustment "empty"
10 s
Adjustment "full"
15 s
Factory reset
20 s
Test
EasyTeach menu of the adjustment
List 1 Easy-Teach (ET) menu of the adjustment
Time interval (seconds)
0 to 3;
LED green: off
3 to 8;
LED green: flashing slowly
8 to 13;
LED green: flashing
13 to 18:
LED green: double pulses
<18;
LED green; 1 Hz flashing
Output values during setting and error function
List 2 Device variants and standard signals
Output standard signal
Level measurement values
Factory reset
Adjustment "empty" active
(Period: 15...60 seconds)
Adjustment "empty" successful
(Period: 5 seconds)
Adjustment "full" active
(Period: 5...20 seconds)
Adjustment "full" successful
(Period: 5 seconds)
Setting warning
Fault / Malfunction
16
Menu point
Comment / Function
-
Without a function
Adjustment
Saves the empty measured values:
"empty"
Factory calibration is loaded
During the execution: LED flashes quickly, flashing fre-
quency is increased by three steps depending on progress
Adjustment
Calibration factor is recalculated:
"full"
During the execution LED flashes quickly
Factory
Settings are reset
reset
Test
Output 0-100 %, alternating
Aout
IL4
-
4...20 mA
0 %
4 mA
25 %
8 mA
50 %
12 mA
75 %
16 mA
100 %
20 mA
0 %
4 mA
-
2 mA
Flashing T=300 ms
Flashing T=150 ms
Double pulses
Flashing T=1 s
IL20
UL0
20...4 mA
0...10 V
20 mA
0 V
16 mA
2.5 V
12 mA
5 V
8 mA
7.5 V
4 mA
10 V
4 mA
0 V
2 mA
0 V
UL10
10...0 V
10 V
7.5 V
5 V
2.5 V
0 V
0 V
0 V