Factory reset
• By applying / connecting the teach wire to the supply voltage (UB+) or by holding the magnet to the
teach spot, the mode change is activated.
• The setting is made by disconnecting the teach wire or removing the magnet from the teach spot at the
menu item factory reset, see Table 1 (setting menu).
• The teach input is inactive during initialization and setting.
• The setting is displayed via the LED and via the output.
Factory reset
Aout = 0 %
Immediately, the adjustment "empty" and the adjustment "full" are deleted, the factory reset becomes
active again.
Test
It is for controlling the output Aout for testing the system function in the application.
• By applying / connecting the teach wire to the supply voltage (UB+) or by holding the magnet to the
teach spot, the mode change is activated.
• The setting is made by disconnecting the teach wire or removing the magnet from the teach spot at the
menu item test, see Table 1 (setting menu).
• The teach input is inactive during initialization and setting.
• The setting is displayed via the LED and via the output.
Test
Aout = 0-100 %, alternating
As long the teach connection is active.
Maintenance, repair, disposal
• Maintenance for this device is not necessary when used as intended.
• It is not possible to repair the device. If you have any problems, please contact directly your customer
service.
• Please dispose of the device in a way that is environmentally friendly according to the national
regulations.
Time interval 13 to 18 seconds
LED green double pulses single
Time interval > 18 seconds
LED green flashing T= 1s