Programming the Control
CONTROL
SETTINGS
REQUIRED
upon
installation
and
after an extended
power outage.
NOTES:
• WHEN THE TIL*_NSFORMER IS PI,UGGED INTO THE
ELECTRICAL OUTLET (see step 9), 12:00 AM (flashing),
and PRESENT TIME show in the display area. Program the
conuol as insu_ucted below, ff SR -- is flashing, use tile UP (+)
/o\ button to set the correct SR code as ti)lh)ws: SR35 fi)r GNSF35,
SR31 ti)r GXSF39, or SR22 ti)r GXSF27. Ifyou pass by tile correct
code number, use the DOWN (-) W button. Then press the
SEI_ECT button and program the control.
• A "beep" sounds while pressing buttons tor conuol programming.
One beep signals a change in the conuol (fisplay. Repeated beeps
mean the conuol will not accept a change flom tile button you
haw pressed, and you should use another button.
• Toprogramtheconuol,
youwillusetheUP
(+) /o\,
DOWN (-) W and SEI_ECT buttons.
Display
TOUCH or HOLD button
UP(4
SmartWater Softener System- _,J
SELECT button
l&
SET PRESENT
TIME
OF DAY
.....
NOTE:
If tile words PRESENT
TIME do not sh_)w in tile display,
press tile SEI_ECT button
until they do.
1. Press the UP (+) _ or DO_VN (-) _
button
to set. The UP
button
moves the display ahead; the DOWN button
moves the
time backward.
If tile present
time is between
noon
and midnight,
be sure PM
shows
_,
ff-I,_ I"
C ' 0d
I
mEs_r
rl_
NOTE:
Each press of an UP (+) _ or DOWN (-) W button
changes
the time by one minute.
Holding
tile button
in changes
tile time
32 minutes
each second
,_,,_r-_l ' l'-I'-i'
-'_-I_J_
•
2. When tile present
time shows, press SELECT to set. If the present
time is between
midnight
and noon. be sure AM sh_)ws.
SET WATER
HARDNESS
NUMBER
11--7-
NOTE:
If 15 (facto U defauh)
and
/,_!
tLa.RDNESS
do not show in the
display, press SEI_ECT until they do.
1. Press the UP (+)/o\ or DOX.VN (-) _] button
to set w)ur water
hardness
number
in the display. DOWN (-) W moves the display
down u) 1. UP (+) _
moves tile maximum
setting.
NOTE:
Each press of a button
changes
the display by 1 between
1
and 25. Above 25, the display changes 5 at a time (25, 30, 35, etc.).
Hol(fing
a button
in changes
the numbers
twice each second.
2. When your water hardness
number
sh_)ws, press SEI _ECT to set.
NOTE:
If there is clear water iron in your water supply, you will
need to increase
the hardness
setting by 5 for each 1 ppm of clear
water iron in your water supply.
You can get the grains per gallon (gpg) hardness
of your water
supply from a water analysis lalmratory,
or call and ask your local
water department,
if you are on a mmficipal
supply, or call GE
Answer Center ® to request
a water harthless
test kit. If your report
shows hardness
in parts per million
(ppm) simply divide by 17.1 to
get the equivalent
number
of grains per .qallon.
SET REGENERATION
(STARTING)
TIME
NOTE: RECtL_R(;E TIME and a flashing 2:00 AM
(tacto U detault) should show in the display. This is a good
time fi)r regeneration
lo start ((wet in about 2 hours) in most
households because water is not in use. HARD WATER is
bypassed to house fimcets during regeneration.
If no chmage is needed, go m step 2. To change the
regeneration
starting time, fifth)w step 1.
1. Press the UP (+) _ or DOWN (-) W button to set the
desired regeneration
start time.
NOTE: Each press of the buttons changes tim time by l hour.
Holding the buttons in changes the time twice ea(h second.
2. t tess tile SELECT button
once more.
,
la II I
Be sure to observe tile AM or l M, as
_
_
you did when setting the time of day.
The display shows tile present
time of day and RECHARGE
TONIGHT.
I
I
itECHA PGE TON/Gt/T