9.
INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE)
(INTERNAL BLOWER(S) HOOD ONLY)
Using standard 3/8" screws
provided, secure the adapter to the top (or back) of the hood
(2 screws for a 314" x 10"
adapter/damper and 4 screws for a 4%" x 18%" adapter). Seal the adapter to the hood using duct tape. For round ducting, install
an appropriate sized transition and seal the joints with duct tape.
HJ0013
10. INSTALL WOOD MOUNTING STRIP
Measure and mark a level line on wall above cooktop location for the wood
mounting strip (see illustration at right and under step 2). Remove wood mounting
strip from back of hood.
Use no. 10 - 2" flat head screws to secure the mounting strip to the drywall. Make
sure to hit the wall studs.
Due to the weight of this hood, ensure that the wood strip is
attached to all of the available studs (2 studs minimum for a 30"
width hood, more as hood width increases); not into the drywall
alone.
HDO263A
1. Drywall
4, Wall anchor location
2. Wood mounting strip
5. Back of hood outline
3. Flat head screw
6. Wall studs
11. INSTALL ANKE60 RECIRCULATION KIT (NON-DUCTED INSTALLATION ONLY)
Refer to the instructions sheet included with the recirculation kit for details.
12. INSTALL AEE OPTIONAL SOFFIT CHIMNEY
(DUCTED INSTALLATION ONLY)
Refer to the instructions sheet included with the optional soffit chimney.
-10-