the angle of the blade during operation by regulating the height of the two wheels
positioned in front of/behind the squeegee.
6.3.
Mounting and changing the brush/abrasive disks (STANDARD MACHINE).
Never work without the brushes and abrasive disks perfectly installed.
These operations must be performed with the machine off and the head raised
The terms RIGHT and LEFT refer to the forward movement of the machine
Mounting the right brush (or abrasive disk)
• remove the right and left side hatches (fig. L, ref. 2);
• position the right brush (fig. M, ref. 1) under the drive disk (fig. M, ref. 2)
• lift the right brush (fig. M, ref. 1) and turn it clockwise to block it on the drive disk (fig.
M, ref. 3)
Mounting the left brush (or abrasive disk)
• Follow the same procedure as used to mount the right brush, blocking it on the drive
disk by turning it anticlockwise.
Removing the right brush (or abrasive disk)
• rotate the brush anticlockwise (fig. M, ref. 1) to release it from the drive disk (fig. M, ref.
3)
• Replace the right and left side hatches (fig. L, ref. 2);
Removing the left brush (or abrasive disk)
• Follow the same procedure as used to remove the right brush, releasing it from the
drive disk by turning it clockwise.
6.4.
Automatic attachment and release of the microfibre disk/brushes/abrasive
disks (MICRO SCRUB / ECS MACHINE)
Never operate the machine without the disks correctly installed.
ATTACHING:
• Raise the side flaps on both sides and position the disks under the housing, making
sure they rest against the stops to align them with the attachment device.
• Press the brush button (fig. A, ref. 8) and the machine performs the automatic
attachment manoeuvre
RELEASING:
• Turn off the head and suction motors and all devices.
• Press the release button (fig. A, ref. 16) and hold for five seconds. The machine
performs the automatic release manoeuvre.
6.5.
Roller brush assembly and disassembly
Never work without the roller brushes perfectly installed.
ENGLISH
14
IMPORTANT
! DANGER
IMPORTANT
IMPORTANT