1. Provide Electrical Service
CAUTION: Risk of electrical shock. Disconnect the power
before proceeding. Refer to the "Important Safety Instructions"
section.
A Ground-Fault Circuit-Interrupter (GFCI) is recommended for
this circuit.
Local electrical codes may require that electrical work be
performed by a licensed electrician. Follow all local electrical
codes.
Refer to the roughing-in information to determine the proper
circuit location.
The sink controls and system have been prewired at the factory.
Only minor electrical connections are required during installation.
The power wiring and terminal box must be provided by the
customer.
Provide a dedicated 120 V, 15 A, 60 Hz two-wire with ground
circuit for the cook sink.
Locate the junction box away from any water or drain piping.
Install a junction box in the cabinet in the vicinity of the cook
sink's location.
Pull wires from the circuit breaker panel board through the
junction box to the cook sink area.
In the cabinet, route and support the cook sink power wiring in
order to protect the wires from contact with any items that may
be stored in the cabinet. Flexible watertight conduit is
recommended.
Route and support the cook sink power wiring.
1032055-2-B