4. Connect the Wiring
NOTE: This instruction assumes that a licensed electrician has
installed a dedicated 120 V, 15 A, 60 Hz circuit as per the
roughing-in details.
Connect the power and ground wiring to the junction box in
accordance with local code requirements.
Use the two screws to replace the cover on the junction box.
Leave the power turned off at this time.
5. Connect the Plumbing
NOTE: Do not install a garbage disposal on the cook sink drain.
Connect the cook sink drain to the trap as per the trap
manufacturer's instructions.
6. Install the Control Knob
Align the drain control knob to the drain control shaft on the
controller.
Press the drain control knob on the shaft.
Check that the drain control knob will rotate about 3/4 turn in
each direction.
Kohler Co.
Junction Box
From Circuit
Breaker
9