Descargar Imprimir esta página

Honeywell Galaxy 2 Serie Manual De Instalación Y Programación página 143

Ocultar thumbs Ver también para Galaxy 2 Serie:

Publicidad

Especificaciones
SECCIÓN 15: ESPECIFICACIONES
Panel Specifications
Physical
Plastic Box-3 mm polycarb
(with mains transformer and PCB installed)
Metal Box-1.2 mm steel
(with mains transformer and PCB installed)
Electrical
Panel Current Consumption
PSU Type
Mains Input
Back-up Battery
Max recharge time
Operating temperature
PSU Max total load
Grade 2 Rating
Output voltage
Max continuous ripple voltage
Individual 12 V outputs:
Bell+12V
Both Aux+combined
Trigger Header+12V
Switched Outputs:
Trigger Header Outputs
Bell Trigger 1003
Strobe Trigger 1004
Trig Output 1001
Speaker Output:
Speaker output 1002
Fuses:
Mains
Battery (F1)
Aux (F2)
Bell (F3)
Codes
Digits available
Code length
Total variations per code
Manual de instalación y programación de Galaxy 2
2-44+
Width: 300 mm
Height: 250 mm
Depth: 100 mm
Weight: 1.7 kg
Width: 370 mm
Height: 320 mm
Depth: 85 mm
Weight: 4.5 kg
100 mA (max)
A
230 V ac (+10% -15%)
Up to 7.2Ahr 12 V Sealed
Lead-Acid (plastic encl.)
Up to 17Ahr 12 V Sealed
Lead-Acid (metal encl.)
<72 hours
0
0
-10
C to +40
C
1.4 A (nominal temp. and
mains supply)
1 A
Nominal +12 V
0.5 V at max. load
500 mA max
500 mA max
100 mA max
Can sink 30 mA each
Can sink 500 mA max
Can sink 500 mA max
Can sink 30 mA max
8 to 32 ohms or 100 mA in
switched DC mode
500 mA, 20 mm anti-surge
(IEC 127)
1 A, 20 mm anti-surge
500 mA, 20 mm anti-surge
500 mA, 20 mm anti-surge
0 - 9
4 - 6 digits
6
5
4
10
+ 10
+ 10
= 1,110,000
Tabla 32. Especificaciones del panel
2-20
Width: 300 mm
Height: 250 mm
Depth: 100 mm
Weight: 1.7 kg
Width: 300 mm
Height: 255 mm
Depth: 115 mm
Weight: 3.9 kg
70 mA (max)
A
230 V ac (+10% -15%) @ 50Hz
Up to 7.2Ahr 12 V Sealed Lead-Acid
(plastic encl.)
Up to 12Ahr 12 V Sealed
Lead-Acid (metal encl.)
<72 hours
0
0
-10
C to +40
C
1.0 A (nominal temp. and mains supply)
600 mA
Nominal +12 V
0.5 V at max. load
500 mA max
500 mA max
100 mA max
Can sink 30 mA each
Can sink 500 mA max
Can sink 500 mA max
Can sink 30 mA max
8 to 32 ohms or 100 mA in switched DC
mode
200 mA, 20 mm anti-surge (IEC 127)
1 A, 20 mm anti-surge
500 mA, 20 mm anti-surge
500 mA, 20 mm anti-surge
0 - 9
4 - 6 digits
6
5
4
10
+ 10
+ 10
= 1,110,000
Series

Publicidad

loading