Installation
Instructions
ELECTRICAL REQUIREMENTS
FOR ELECTRIC DRYERS
This dryer must be connected
to an individual
branch circuit, protected
by the required time-
delay fuses or circuit breakers. A three- or four-
wire, single phase, 120/240V or 120/208V, 60Hz,
30-amp
circuit is required.
If the electric supply does not meet the above
specifications,
then call a licensed electrician.
GROUNDING
INSTRUCTIONS
This dryer must be connected
to a grounded
metal,
permanent
wiring system, or an equipment-
grounding
conductor
must be run with the circuit
conductors
and connected
to the equipment
grounding
terminal
on the appliance.
CONNECTING
DRYER USING 4-WIRE
CONNECTION
(MUST BE USED FOR
MOBILE HOME INSTALLATION)
NOTE: Since January
1, 1996, the National Electrical
Code requires that new constructions
utilize a
4-wire connection
to an electric dryer. A 4-wire cord
must also be used where local codes do not permit
grounding
through
the neutral.
3-wire connection
is NOT for use on new
construction.
Remove ground
strapand
_
Relocategreenground
discard.Keep
E1
HotWire
screwhere
green groued
\[
._ _"'_--
i
/
_'"
_\'_-[:¢_._1.I
Strain Relief
/
Screws (3)_
\. _i'_l_'_y_k_
Bracket
,]
NeutralS\
HotWire,,_ IJ
_'_"
Cover
_'_----_,_
4 #10AWG minimumcopper
o
-_---_-J conductorsor 120/240V30Apower
supplycord kit markedfor usewith
dryersand providedwith closedloop
or spadeterminalswith upturnedends
(not supplied)
CONNECTING
DRYER USING 4-WIRE
CONNECTION
(MUST BE USED FOR
MOBILE HONE INSTALLATION)
(cont.)
1. Turn off the circuit breaker(s)(30
amp) or remove
the dryer's circuit fuse at the electrical
box.
2. Be sure the dryer cord is unplugged
from the wall
receptacle.
3. Remove the power cord cover located at the
lower back.
4. Remove and discard ground strap. Keep the
green ground screw for step 7.
5. Install 3//4 in. UL-recognized
strain relief to power
cord entry hole. Bring power cord through
strain
reliefi
6. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws
of the terminal
block (marked L1 and L2).
B. Connect the neutral (white)line
to the center
of the terminal
block (marked N).
7. Attach ground wire of power cord with the green
ground screw (hole above strain relief bracket).
Tighten all terminal
block screws (3) completely.
8. Properly secure power cord to strain relief.
9. Reinstall the coven
-A WAR N ING - NEVER
LEAVE
THE
COVER OFF OF THE TERMINAL BLOCK.
21