Typical Under
Oven
Counter
Installation
of an Electric Built-in
with a Cooktop
Mounted
Above
All mounting
hardware
must be
used to secure the built-in oven to
the cabinets. Refer to the built-in
oven installation instructions.
Junction box must
be located approx.
3" to the left of
the built-in oven
cutout.
This cooktop may
be installed over
certain built-in elec-
tric oven models.
Side filler panels are necessary to iso-
late the unit from adjoining cabinets.
Panel height should allow for installa-
tion of approved cooktop models. See
"Typical Gas Cooktop Installation Over
an Electric Built-in Oven Installed Un-
der the Counter" on next page.
208/240 Volt
grounded junction
box for built-in oven.
36"
(91.4 cm)
Min.
Cut an opening in wood base minimum 4"
(10.2 cm) x 4" (10.2 cm) to route armored
cable to junction box.
Unit will
overlap
cutout
(minimum)
edges by
1 " (2.5cm)
4 1/2" (11.4 cm)
Max.*
Use 3/4" (1.9 cm)
plywood, installed on
two runners, flush with
toe plate. Base must be
capable of supporting
150 pounds (68 kg) for
27" models and 200
pounds (90 kg) for 30"
models.
If no cooktop is installed directly
over the oven unit, 5" (12.7 cm)
maximum is allowed.
CUTOUT DIMENSIONS (inches)
OVEN SIZE
E
F
G
Min.
Max.
Min.
Max.
30"
271/4"
281/4"
281/2"
29"
231/2"
(76.2 cm)
(69.2 cm) -
(71.8 cm)
(72.4 cm) - (73.7 cm)
(59.7 cm)
27"
271/4"
281/4"
247&"
251/4"
231/2"
(68.6 cm)
(69.2 cm) -
(71.8 cm)
(63.2 cm) - (64.1 cm)
(59.7 cm)
Figure 3