Electrical Installation
The models stated on the front cover are either dual-
rated, designed to be connected
to either 208/240V
AC,
60 Hz, 4-wire, single-phase
power supply, or rated at
120V AC, 60 Hz and use a NEMA 5-20 plug to connect
to a dedicated
120 V microwave circuit.
208/240
V models may also be combined
with some
Bosch Built-in Ovens and can be connect directly to the
combo appliance. To do this, please refer to detailed
instructions
with the Bosch Combination
Kit.
WARNING
When connected
to a 4 or 5-wire, 120/208-Volt
3-
phase power supply; the phase C conductor
is not
required for the operation
of the appliance.
Model
Connection
Circuit
Requirements
HMC80251UC
4 wire conduit
208 V,
20 Amps
cable
60 Hz
240 V,
20 Amps
60 Hz
120 V,
20 Amps
60 Hz
120 V,
20 Amps
60 Hz
HMC80151UC
NEMA 5-20
HMC87151UC
NEMA 5-20
Electrical
Connection
with Plug
HMC87151UC
HMC80151UC
Electrical Requirements:
o a three prong grounded outlet
o 120 V, 60 Hz, AC only
o 20 Amp electrical supply with a fuse or a circuit
breaker
This product must be connected
to a supply circuit of the
proper voltage and frequency. Wire size must conform to
the requirements
of the National Electric Code or the
prevailing
local code for this rating. The power supply
cord and plug should be brought to a separate 20-amp
branch circuit single grounded outlet. The outlet box
should be located in the area behind the appliance (see
section Cabinet Dimensions).
The outlet box and supply
circuit should be installed by a qualified electrician and
conform to the National Electrical Code or the prevailing
local code.
The voltage used must be the same as specified
on this
microwave oven. Using a higher voltage is dangerous
and may result in a fire or oven damage. Using a lower
voltage will cause slow cooking. The dealer is not
responsible
for any damages resulting from the use of
the oven with any voltage other than specified.
Electrical Connection
with Wire Conduit
HMC80251UC
The electrical supply should be a 4-wire single-phase
AC.
Install a suitable conduit box (not furnished). An
appropriately-sized,
UL-listed conduit connector
must be
used to correctly attach the conduit to the junction box.
NOTICE:
Local Codes may vary; installation, electrical
connections
and grounding
must comply with all
applicable
local codes.
If local codes permit grounding through the electrical
supply neutral, connect both the white neutral wire and
the bare ground wire from the oven to the white neutral
electrical supply wire.
Electrical Connection
The four-wire connection
is preferred, but where local
codes permit, the three wire connection
is also
acceptable.
WARNING
When connected
to a 4 or 5-wire, 120/208-Volt
3-
phase power supply; the phase C conductor
is not
required for the operation of the appliance.
Four-wire Connection
Ungrounded
Neutral
power supply
junction
wires
green or bare
wire
green wire
white wires
UL
connector
,,_
cable from
oven
o Connect the red oven wire to the red electrical supply
wire (hot wire).
o Connect the black oven wire to the black electrical
supply wire (hot wire).
o Connect the white neutral oven wire to the white
neutral (not bare or green ground) electrical supply
wire.
o Connect the green ground oven wire to the bare or
green ground electrical supply wire.