2. 3. COMMISSIONING
After having affixed the roller shutter to the roller tube,
check that when the roller shutter is in the lower end limit
position, the rigid link is correctly positioned and that the
first slat is vertically between the runners (as per F). If
necessary, adjust the number of slats used to improve the
position of the rigid link when the roller shutter is in the
lower end limit position.
Always refer to the manufacturer's size and weight charts
and fitting recommendations for the rigid links to select
those suited to the roller shutter used.
Use at least 2 rigid links to attach the roller shutter to the roller tube.
Switch the power back on.
1)
Press the "Up" button at the control point:
-
If the roller shutter rises, the wiring is correct and
-
commissioning is finished.
If the roller shutter is lowered, go to the next step.
-
Switch off the power.
2)
Reverse the brown wire and the black wire connected to the
-
control point.
Switch the power back on.
3)
Press the "Up" button to check the direction of rotation.
-
2. 4. TIPS AND RECOMMENDATIONS FOR INSTALLATION
2. 4. 1. Questions concerning the ILMO 2 40 WT?
Problems
The roller shutter is
The wiring is incorrect.
turning in the wrong
direction.
The roller shutter is
The wiring is incorrect.
not operational.
The drive is hot.
The control point is not compatible.
The roller shutter
The roller shutter is encountering friction
stops too soon.
when it moves: friction along the runners and
case, interference between the roller tube and
the drive, etc.
The drive has been installed in a new roller
shutter.
The roller shutter
The mountings used are not correct.
does not stop when it
reaches the lower end
limit position.
The roller shutter
The roller shutter locking system in the upper
does not stop when it
position is not correct.
reaches the upper end
limit position.
16
Possible causes
Copyright © 2018 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
F
F
1
ON
2
OFF
3
ON
Solutions
Check the wiring and modify it if necessary.
Check the wiring and modify it if necessary.
Wait for the motor to cool down.
Check for compatibility and replace the control point if
necessary.
Check the roller shutter installation and correct any
friction.
If the problem continues, restore the drive to its original
configuration.
Restore the drive to its original configuration, see the
section entitled "Restoring the original configuration".
Check that the roller shutter is mounted to the roller tube
using rigid links.
Check that the roller shutter is fitted with end stops
screwed onto the last slat, fixed or removable stops
incorporated in the runners or an end slat acting as an
end stop.