Descargar Imprimir esta página

Toshiba Carrier MMY-MUP0721FT6P-UL Manual Del Propietário página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

Louver lock (Fixing the angle of the louvers)
You can set and fix the angle of louvers individually for each air outlet.
NOTE
• For models that "Louver setting" is not available, the message "No function" is displayed.
• Push [
Return] to not fi x the changes, so conditions are as before changes, and return to the "Louver setting"
screen.
• To cancel "Louver lock", push [
] and [
• When the operation mode is "Cool" or "Dry", performing "Louver lock" at position (4) or (5) may cause
condensation.
• For group connections, refer to the Owner's Manual for the wired remote control.
• " 
  " is displayed when "Louver lock" is set.
27-EN
1140902101_EN FR ES.indb 14
1140902101_EN FR ES.indb 14
1
In "Menu", select "Louver setting", and
push [ 
Set/Fix]
2
Push [ 
 ] and [ 
 ] to select "Louver
lock", and then push [ 
Set/Fix]
3
Push [ 
 ] and [ 
 ] to select louvers
Louver 1
Louver 2
Louver 3
Louver 4
For louver numbers of each indoor unit, refer to
<Individual louver (Select wind direction for each
air outlet)>.
4
Push [ 
 ] and [ 
 ] to select a louver
angle (wind direction)
Push [ 
 ] to raise a louver and push [ 
lower a louver.
(1)
(2)
(3)
(4)
(5)
5
Push [ 
Set/Fix]
Return to the "Louver setting" screen.
6
Push [ 
Return]
"    " is displayed.
When doing group connections, the screen for
selecting units is displayed, so push [ 
to display "    " .
] to set louver not locked for the louver angle of each louver.
4-Way Cassette Type
When cooling
Point the louver horizontally.
When heating
Point the louver downward.
All louvers
 ] to
The louver automatically closes when running is
stopped.
In pre-heating mode, the louver points upward.
The swing indication appears on the remote
Louver not
control even in pre-heating mode, but the actual
locked
swing starts only after pre-heating is complete.
1-Way Cassette Type
When cooling
Point the louver horizontally to send cool air across the
entire room.
Return]
When heating
Point the louver downward to send heated air to the
floor.
– 14 –
The louver automatically closes when running is
stopped.
In pre-heating mode, the louver points upward.
The swing indication appears on the remote
control even in pre-heating mode, but the actual
swing starts only after pre-heating is complete.
Under Ceiling Type
Vertical adjustment
When cooling
Point the louver horizontally to send cool air across the
entire room.
When heating
Point the louver downward to send heated air to the
floor.
The louver automatically closes when running is
stopped.
In pre-heating mode, the louver points upward.
The swing indication appears on the remote
control even in pre-heating mode, but the actual
swing starts only after pre-heating is complete.
Horizontal air flow adjustment
To change the horizontal air flow direction, point the
vertical louvers inside the horizontal louver in your
preferred direction.
11/14/23 7:07 PM
11/14/23 7:07 PM
EN
FR
ES
28-EN

Publicidad