5.3 PRIMER
Press  the  primer  bulb  to  inject  fuel  into  the 
carburettor  intake  manifold  to  facilitate  start-up 
when the engine is cold (fig. 10.F).
5.4 HANDLE FOR MANUAL START
Enables manual starting of the engine (fig. 10.C).
5.5 ELECTRIC STARTER
CONTROL (OPTIONAL)
Enables electric starting of the engine (fig. 10.E) 
when the machine is connected to the electric 
mains using the specific plug (fig. 10.D).
5.6 AUGER CONTROL
Activates auger rotation.
• To activate auger rotation, lift the control
(fig. 6.A) until it meets the handle. 
• When  the  clutch  is  released,  auger  rotation 
stops and the lever automatically returns to the 
start position.
5.7 CHUTE
ADJUSTMENT CONTROL
Rotation of the discharge chute is adjusted using
the handle so that snow discharge can be aimed 
in the required direction.
• Turn the knob (fig. 8.A) to adjust the chute.
• Turn the deflector handle (fig. 9.A) to adjust the 
direction.
6. USING THE MACHINE
The safety regulations to follow during
machine use are described in chap. 2. Strictly
comply with these instructions to avoid
serious risks or hazards.
6.1 PREPARATION
Before  using  the  machine  check for  fuel  and  the 
oil level. For refuelling and oil top-up methods and 
precautions (see par. 7.2 and par. 7.3).
AND
DEFLECTOR
6.2 SAFETY CHECKS
Ensure you have understood the contents before 
proceeding. Run the following safety checks and 
check the results correspond to those outlined in 
the tables.
Always carry out the safety checks before
use.
Object
Fuel lines and
connections.
Electrical cables.
Oil lines
Test driving
6.3 ENGINE
TESTING
Action
Start the machine 
(par. 6.3)
Press the auger
control (fig. 6.A)
Release the auger control. The auger stops.
If any of the results fails to match the
indications provided in the following table, do
not use the machine! Take it to a service centre
to be checked and repaired if necessary.
6.4 START-UP / OPERATION
1. Insert the safety key (fig. 10.B).
6.4.1 Cold start
1. Engage the choke (fig. 10.G).
2. Press the primer bulb (fig. 10.F) twice or three 
times.  Make  sure  that  the  hole  is  covered  by 
your finger when pressing the bulb.
3. Start, using the electric control (par. 6.4.4) or
manual control (par. 6.4.3).
4. Disconnect the choke (fig. 10.G).
IMPORTANT Before starting work with the
machine, wait a few minutes for the oil to warm up.
6.4.2 Warm start
1. Check the choke is disconnected (fig. 10.G).
2. Start the machine electrically or manually (see 
below).
EN - 6
Result
No leaks.
All insulation intact.
No mechanical damage.
No leaks.
No damage.
No abnormal vibrations.
No abnormal sound.
AND
AUGER
OPERATION
Result
The auger stays stopped.
The auger starts to rotate.