Descargar Imprimir esta página

Atlas Copco ETD DS7-20-10S Instrucciones Originales Del Producto página 8

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
Safety Information
Decommissioning
Recycling instruction
When a product has served its purpose it has to be
recycled properly. Dismantle the product and recy-
cle the components in accordance with local legis-
lation.
Batteries shall be taken care of by your national
battery recovery organization.
Technical data
Technical data
Noise and vibration emission
Noise (in accordance
with ISO15744)
Sound pressure level
Sound power level
Uncertainty
This equipment is intended for fixtured applica-
tions. The noise emission is given as a guide to the
machine-builder. Noise and vibration emission
data for the complete machine should be given in
the instruction manual for the machine.
Noise and Vibration Declaration
Statement
These declared values were obtained by laboratory
type testing in accordance with the stated standards
and are suitable for comparison with the declared
values of other tools tested in accordance with the
same standards. These declared values are not ade-
quate for use in risk assessments and values mea-
sured in individual work places may be higher.
The actual exposure values and risk of harm expe-
rienced by an individual user are unique and de-
pend upon the way the user works, the workpiece
and the workstation design, as well upon the expo-
sure time and the physical condition of the user.
We, Atlas Copco Industrial Technique AB, can-
not be held liable for the consequences of using the
declared values, instead of values reflecting the ac-
tual exposure, in an individual risk assessment in a
work place situation over which we have no con-
trol.
8
dBA
<70
-
-
© Atlas Copco Industrial Technique AB - 9836 1724 00
This tool may cause hand-arm vibration syndrome
if its use is not adequately managed. An EU guide
to managing hand-arm vibration can be found by
accessing
http://www.pneurop.eu/index.php
selecting 'Tools' then 'Legislation'.
We recommend a programme of health surveil-
lance to detect early symptoms which may relate to
noise or vibration exposure, so that management
procedures can be modified to help prevent future
impairment.
Service instructions
Trouble shooting schedule
Trouble-shooting
If the nutrunner does not start
Is the POWER FOCUS in RUN mode?
Check that the correct POWER FOCUS is used
(S4).
Check the fuses for the drive part.
Check Drive parameters, refer to the ASL of the
POWER FOCUS/ drive unit.
Check the earth fault circuit breaker inside the
drive. Should it have tripped, make sure to find the
primary fault before resuming operation.
If the tool becomes abnormally hot
With proper adjustment the tool can handle any
normal line jobs that an operator sustains.
What can cause overheating are combinations of
some factors: torque above rated, too low speed,
too long ramp time (motor has to give high torque
for a long time), very high prevailing torque, very
soft joints, short cycle time.
To correct, look over speed, ramp time, tightening
strategy.
One stage and Ergoramp are most heat conserving
when applicable. Please refer to the ASL of your
POWER FOCUS.
If the above corrections are not enough, choose a
tool of the next higher capacity.
Remarque
De nombreux évènements dans l'environnement
d'exploitation peuvent affecter le processus de ser-
rage et nécessiteront une validation des résultats.