 Put the lens with different beam angle gently in place. Please note that the beam angle is indicated in the
center of the lens.
 Fasten the metal lens cover with the 4 screws.
 Put the protective glass back in place and fix it with the 4 screws.
 Done!

OVERHEAD RIGGING

 Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
 Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
 Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
 The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
 Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
 Always use a certified safety cable (number 3 on the
picture) that can hold 12 times the weight of the
device when installing the unit. This secondary
safety attachment should be installed in a way that
no part of the installation can drop more than 20cm if
the main attachment fails.
 The device should be well fixed; a free-swinging
mounting is dangerous and may not be considered!
 Don't cover any ventilation openings as this may
result in overheating.
 The operator has to make sure that the safety-
relating and machine-technical installations are
approved by an expert before using them for the first
time. The installations should be inspected every
year by a skilled person to be sure that safety is still
optimal.
1. Optional Quick Clamp
2. Special omega clamp (included)
3. Optional safety cable
BRITEQ
®
OPERATION MANUAL
3/69
ENGLISH
HOW TO SET UP THE UNIT
CONTROL PANEL:
1. DISPLAY shows the various menus and the selected functions.
2. LEDS
3. BUTTONS
4. REMOTE CONTROL INPUT: Used to connect a simple CA-8 hand controller while the unit is used in
standalone or master/slave mode.
5. SENSITIVITY: Used to adjust the sensitivity of the micro when the unit is used in standalone or
master/slave mode.
6. DMX INPUT/OUTPUT: used for DMX512 linking. Use good quality 3pin XLR M/F balanced cable to link
the units together.
7. MAINS INPUT: with IEC socket and integrated fuse holder, connect the supplied mains cable here.
MAIN MENU:
 To select any of the pre-set functions, press the MENU button up to when the required one is shown on
the display.
 Select the function with the ENTER button. The display will blink.
 Use DOWN and UP button to change the mode.
 Once the required mode has been selected, press the ENTER button to select. After 8 seconds the display
will automatically return to the main functions without any change. To go back to the functions without any
change press the MENU button. The main functions are shown on the right.
Used to set the starting address in a DMX setup.
 Press the MENU button until
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP buttons to change the DMX512 address.
 Once the correct address shows on the display, press the ENTER button to save it.
BT-36 II
BRITEQ
DMX
On
DMX input present
MASTER
On
Master mode
SLAVE
On
Slave mode
SOUND
Flashing
Sound activation
MENU
To select the programming functions
DOWN
To go backward in the selected functions
UP
To go forward in the selected functions
ENTER
To confirm the selected functions
DMX512 Address Setting
is shown on the display.