ZeRO ReSeT STePS - ELITE 4500 Scopes
1. Remove the adjustment dial nut (see photo on previous page).
2. Pull the adjustment dial away from the turret and rotate it so that "0"
will be aligned with the vertical index line on the turret.
3. Replace the adjustment dial nut and tighten it to secure the dial in
place.
ZeRO ReSeT STePS - ELITE 6500 Scopes
1. Pull the adjustment dial straight up (see photo on previous page).
2. Rotate the dial so that "0" is aligned with the vertical index line on the
turret.
3. Push the adjustment dial back down into place.
VARIABLe POWeR AdJUSTMenTS
To change magnification, simply rotate the Power Selector Ring to align the
desired number on the power scale with the index dot. When still-hunting
or stalking game, a variable scope should be set to the lowest power. You then
have the widest field of view for quick shots at close range. Higher powers
should be reserved for precise long-range shots.
WARNING: A scope should never be used as a substitute for either a binocular or spotting
scope. It may result in your inadvertently pointing the gun at another person.
SIde FOCUS (PARALLAx AdJUSTMenT) (select 4500 and all 6500
models)
You may have noticed that placing your eye at
different positions behind the scope's eyepiece causes
the reticle crosshairs to appear to move around to
different points on your target. This is called "parallax
error" (target and reticle are not in the same focal
plane), and it becomes more noticeable (and more
of a problem) at shorter distances and/or when the
scope is set to higher powers.
Some Elite riflescopes provide an adjustment for parallax compensation,
which works by moving an internal optical element until the target (based
on its distance) appears in the same plane of focus as the reticle. To adjust
the parallax setting of your scope, start by lining up the estimated distance
(marked on the side focus knob) to your target with the index line on
the body of the scope. If the target image is clear, your parallax is set. If
the target image appears out of focus, turn the side focus knob in either