Descargar Imprimir esta página

Selco Quasar 320 SMC Classic Instrucciones De Uso página 37

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 95
3
Wire speed
Allows the regulation of the wire feed rate.
Minimum 0.5 m/min, Maximum 22 m/min, Default
1.0m/min
4
Current
Allows the regulation of the welding current.
Minimum 6A, Maximum Imax
5
Part thickness
Allows the thickness of the part being welded to be set.
Allows the setting of the system via the regulation of the
part being welded.
6
Corner bead
Lets you set bead depth in a corner joint.
7
Voltage
Allows the regulation of the arc voltage.
Allows regulation of the arc length during welding.
Manual MIG/MAG:
High voltage = long arc
Low voltage = short arc
Minimum 5V, Maximum 55.5V
Synergic MIG/MAG:
Minimum -5.0, Maximum +5.0, Default syn
10
Pre-gas
Allows you to set and adjust the gas flow prior to striking
of the arc.
Permits filling of the torch with gas and preparation of
the environment for welding.
Minimum off, Maximum 25 sec., Default 0.1 sec.
11
Soft start
Permits adjustment of the wire feed speed in the phases
prior to arc striking.
Given as a % of the wire speed set.
Permits striking at reduced speed, therefore softer and
with less spatter.
Minimum 10%, Maximum 100%, Default 50% (syn)
12
Motor slope
Allows you to set a gradual transition between the
sparking wire speed and the welding wire speed.
Minimum off, Maximum 1.0 sec., Default off
15
Burn back
Permits adjustment of the wire burn time, preventing
sticking at the end of welding.
Permits adjustment of the length.
Permits adjustment of the length of the piece of wire
outside the torch.
Minimum -2.00, Maximum +2.00, Default syn
16
Post-gas
Permits setting and adjustment of the gas flow at the
end of welding.
Minimum off, Maximum 10 sec., Default 2 sec.
24
Bilevel (4 Step - crater filler)
Permits adjustment of the secondary wire speed in the
bilevel welding mode.
If the welder now presses and releases the button quickly,
"
" can be used; by pressing and releasing it quickly
again, "
" is used again, and so on.
Parameter setting: Percentage (%).
Minimum 1%, Maximum 500%, Default off
25
Initial increment
Allows regulation of the wire speed value during the
first "crater-filler" welding phase.
Makes it possible to increase the energy supplied to
the part during the phase when the material (still cold)
requires more heat in order to melt evenly.
Minimum 20%, Maximum 200%, Default 120%
26
Crater filler
Allows regulation of the wire speed value during the
weld closing phase.
Makes it possible to reduce the energy supplied to the
part during the phase when the material is already very
hot, thus reducing the risk of unwanted deformations.
Minimum 20%, Maximum 200%, Default 80%
27
Initial increment time
Lets you set the initial increment time. Lets you auto-
mate the "crater filler" function.
Minimum 0.1s, Maximum 99.9s, Default Off
28
Crater filler time
Lets you set the "crater filler" time. Lets you automate
the "crater filler" function.
Minimum 0.1s, Maximum 99.9s, Default Off
29
(Crater filler, MIG Bilevel) slope
Crater filler:
Allows you to set a gradual passage between the initial
wire speed (initial increment) and the welding wire
speed.
Allows you to set a gradual passage between the weld-
ing wire speed and the final wire speed (crater filler).
MIG Bilevel:
Allows a smooth step to be obtained between the peak
wire speed and the basic wire speed, having a more or
less soft welding arc.
Parameter set in seconds (s).
Minimum 0.1s, Maximum 10.0s, Default off
30
Spot welding
Allows you to enable the "spot welding" process and
establish the welding time.
Minimum 0.1s, Maximum 25s, Default off
31
Pause point
Allows you to enable the "pause point" process and
establish the pause time between one welding opera-
tion and another.
Minimum 0.1s, Maximum 25s, Default off
32
Secondary voltage (MIG Bilevel)
Allows regulation of the secondary pulsation level voltage.
Makes it possible to obtain greater arc stability during
the various pulsation phases.
Minimum -5.0, Maximum +5.0, Default syn
33
Secondary inductance (MIG Bilevel)
Allows regulation of the secondary pulsation level
inductance.
Makes it possible to obtain a quicker or slower arc to
compensate for the welder's movements and for the
natural welding instability.
Low inductance = reactive arc (more spatter).
High inductance = less reactive arc (less spatter).
Minimum -30, Maximum +30, Default syn
202
Inductance
Allows electronic regulation of the series inductance of
the welding circuit.
Makes it possible to obtain a quicker or slower arc to
compensate for the welder's movements and for the
natural welding instability.
Low inductance = reactive arc (more spatter).
High inductance = less reactive arc (less spatter).
Minimum -30, Maximum +30, Default syn
331
Voltage (Synergic MIG/MAG)
Lets you set welding voltage.
500
Allows access to the higher set-up levels:
USER: user
SERV: service
SELCO: Selco