Shutting down
1. After each use, if you have applied chemicals, place chemical hose into container of clean water and draw clean water through
chemical injection system to rinse system thoroughly.
NOTE
Failure to do so could cause damage to the pump.
2. Turn engine off.
NOTE
NEVER turn the water off with the engine running.
3. Turn water source off.
4. Pull trigger on spray gun to relieve any water pressure in hose or spray gun.
5. See "Storage" section in this manual for proper procedures.
5. MAINTENANCE
WARNING!
When performing maintenance, you may be exposed to hot surfaces, waterpressure or moving parts that
can cause serious injury or death!
Before performing any maintenance or repair, disconnect spark plug wire, let engine cool and release all water pres-
sure. The engine contains flammble fuel. DO NOT smoke or work near open flames while performing maintenance. To
ensure efficient operation and longer life of your pressure washerm a routine maintenance schedule should be prepared and
followed. If the pressure washer is used in unusual conditions, such as high-temperature of dusty conditions, more frequent
maintenance checks will be required.
Engine
Consult the engine owner's manual for the manufacturers recommendations for any and all maintenance.
To check oil
1. Remove dipstick/oil plug from pump and wipe clean.
2. Insert dipstick/oil plug fully into pump, then remove it.
3. Oil level is correct when oil covers the lower 1/2" of end of dipstick/oil plug.
How to change pump oil
1. Loosen dipstick/oil plug.
2. Place container under the oil drain plug.
3. Remove oil drain plug.
4. After oil is drained, replace oil drain plug. Tighten securely.
5. Remove dipstick/oil plug and fill with oil.
6. Replace dipstick/oil plug and tighten securely.