Descargar Imprimir esta página

Omega SILVERSTONE 250 Manual De Instrucciones página 34

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
Spray wand
If the nozzle becomes clogged with foreign materials such as dirt, excessive pressure may develop. If the nozzle becomes
partially clogged or restricted, the pump pressure will pulsate. Clean the nozzle immediately using the nozzle kit supplied and
the following instructions:
1. Shut off the pressure washer and turn the water supply.
2. Pull trigger on gun handle to relieve any water pressure.
3. Disconnect the spray wand from the gun.
4. Remove the high-pressure nozzle from the spray wand. Remove any obstructios with the nozzle cleaning tool provided and
backflush with clean water.
5. Direct water supply into spray wand end to backflush loosened particles for 30 seconds.
6. Reassemble the nozzle to the spray wand.
7. Reconnect spray wand to gun and turn on water supply.
8. Start pressure washer and place wand into high pressure setting to test.
How to clean the water inlet filter
This screen filter should be checked periodically and cleaned if necessary.
1. Remove filter by grasping end and removing it from water inlet of pump.
2. Clean filter by flushing it with water on both sides.
3. Reinsert filter into water inlet of pump. NOTE: cone side faces out.
NOTE
Do not operate pressure washer without filter properly installed.