I_
Risk of Bursting.
Water will
condense in the air tank. If not
drained, water will corrode and
weaken the air tank causing a risk
of air tank rupture.
6.
After the water has been drained,
close the drain valve (clockwise).
The air compressor
can now be
stored.
NOTE: If drain valve is plugged,
release all air pressure.
The valve
can then be removed, cleaned, the
reinstalled.
IMPORTANT:
Do not operate the
compressor
with the air filter
removed.
3.
If dirty, rinse air filter with warm
water and squeeze dry.
4.
Replace air filter and air filter
cover.
NOTE: If the air filter is extremely
dirty it will need to be replaced. Refer
to the "Repair Parts" for the correct
part number.
Air Compressor
Pump
Intake
and Exhaust
Valves
Air Filter Inspection
and
Replacement
Risk of Burns.
Compressor
head
and cylinder sleeve are very hot.
Do not touch. Allow compressor to
cool prior to servicing
A dirty air filter will not allow the
compressor to operate at full
capacity.
Keep the air filter clean at
all times.
1.
Remove the air filter cover.
2.
Remove the air filter and make
sure it is clean.
Once a year have a Trained Service
Technician check the air compressor
pump intake and exhaust valves.
Motor
The motor has an automatic reset
thermal overload protector. If the
motor overheats for any reason, the
overload protector will shut off the
motor. The motor must be allowed to
cool down before restarting.
The
compressor
will automatically
restart
after the motor cools.
If the overload protector
shuts the
motor off frequently, check for a
possible voltage problem.
Low
1
ir Filter
J/
2.1"
Air Filter
voltage can also be suspected when:
The motor does not get up to full
power or speed.
Fuses blow out when starting
the motor; lights dim and remain
dim when motor is started and is
running.
17_ ENG