5- Once you have chosen a programme for each day, confirm your selection
by pressing
. The days of the week will succesively scroll on display with
the programmes that you set for them (P1, P2, P3, CONF or ECO) . To exit the
programme viewing mode, press
Viewing the programmes that you have selected
- From Auto, Comfort, Eco or Frost protection mode, press
Press
twice, the programme for each day of the week (Comfort, Eco,
P1, P2 or P3) .
- To exit the programme viewing mode, press
• Manual and temporary exemption from a running programme
This function allows you to change the setting temperature temporarily until
the next scheduled change in temperatre or the transition to 00:00 .
Example :
1- The device is in Auto mode, the running programme is Eco 15,5°C .
2- By pressing
or
, you can change temporarily the desired
temperature up to 18°C .
Note: The cursor corresponding to the operation mode, i .e Eco mode in
our example, is blinking during the duration of the temporary derogation .
3- This change will be automatically cancelled at the next change of
programme or transition to 00:00 .
11.10 Open window detection, energy savings
• Important information about the open window detection
Important: the open window detection is sensitive to temperature
variations . The device will react to the window openings in accordance
with different parameters: temperature setting, rise and fall of temperature
in the room, outside temperature, location of the device . If the device is
located close to a front door, the detection may be disturbed by the air
caused by opening door . If this is a problem, we recommend that you
disable the automatic mode open window detection . You can, however,
use the manual activation .
Cod . 1910000000276 - nv04
twice .
for 5 seconds .
twice .
3
3
3
• Overview
Lowering temperature cycle by setting frost protection during ventilation
of a room by opened window . You can access the open window detection
from the Comfort, Eco and Auto modes .
- Automatic activation, the lowering temperature cycle starts as soon as
the device detects a temperature change .
- Manual activation, the cycle of lowering temperature starts by pressing
a button .
• Automatic activation (factory settings)
The device detects a temperature fall . An opened window, a door to the
outside, can cause this temperature fall .
Note: The difference between the air from the inside and the outside
must cause a significant temperature fall to be perceptible by the device .
This temperature drop detection triggers the change to Frost Protection
mode .
• Manual activation
By pressing
for more than 5 seconds, the device will switch on Frost
protection mode .
• Frost protection digital meter
When the device performs a lower temperature cycle due to opened
window, a meter appears on the display to show he cycle time . The
counter is automatically reset the next time Frost protection by opened
window is activated (automatic or manual activation) .
• Stop the Frost protection mode
By pressing any button, you stop the Frost protection mode .
Note: If a temperature rise is detected, the device may return to the
previous mode (active mode before the open window detection) .
11.11 Optional: Remotely management by infrared remote control
Your towel rails can be managed by a remote control with infrared transmission
through its IR receiver located on the front of the controller .