Descargar Imprimir esta página

SFA Sanibroyeur Serie Manual De Instalación página 24

Ocultar thumbs Ver también para Sanibroyeur Serie:

Publicidad

EN-US
1. SAFETY
Read the user manual carefully before using your
appliance for the first time.
1.1 IDENTIFICATION OF THE WARNINGS
MEANING
DANGER
This term defines a high risk of danger,
which can lead to death or serious injury,
if not avoided.
WARNING This term defines a medium risk of danger
that can lead to minor to serious injury, if
not avoided.
NOTICE
This term defines dangers to the machine
and its proper operation.
Warning of a general danger.
The danger is specified by indications
given in the table.
Warning about the dangers associated
with the electrical voltage and provides
information about protection against
electrical voltage.
Warning of damage to the boat.
1.2 GENERAL
DANGER
Electrical hazards and risks of cuts.
Ö Never dismantle the appliance.
Ö Don't use your appliance if a cable or
connection plug is damaged.
Ö To avoid danger, have repairs done by
authorized personnel.
Connection errors (observe the polarity) or incorrect
connection invalidate the warranty.
WARNING
Risk of cutting.
Ö Never touch moving parts.
Incorrect use or installation releases SFA from any
liability.
For further information, don't hesitate to contact our
customer service.
DISCONNECT
THE
BEFORE ATTEMPTING ANY WORK ON THE UNIT.
2. DESCRIPTION
2.1 APPLICATION
Sanimarin® Maxlite+S is a bowl fitted with a pump/
macerator to remove the sanitary effluent.
Sanimarin® Maxlite+S is a WC equipped with a pump/
macerator which installed and used correctly will give
reliable and consistent service for many years.
Sanimarin® Maxlite+S macerates and pumps effluents
without disinfection effect.
THIS PRODUCT SHOULD NOT BE USED FOR ANY OTHER
PURPOSE OTHER THAN DESCRIBED HERE.
2.2 OPERATING MODE
Sanimarin® Maxlite+S is controlled by a two-position
switch:
• Add water: bowl flushing command,
• Pump out: maceration and discharge command.
ELECTRICAL
POWER
SUPPLY,
2.3 SCOPE OF SUPPLY
See attached leaflet.
2.4 TECHNICAL DATA
Max. Pumping
10 Ft
height
Max. Horizontal
100 Ft
pumping distance
Supply voltage
12 V or 24 V
Outlet diameter
1 or 1-1/2"
Weight
18 Lbs
2.5 DISPOSAL
The device must not be disposed of as household
waste and must be disposed of at a recycling point
for electrical equipment. The disposal of electrical and
electronic waste, recycling and recovery of any form of
used appliances contribute to the preservation of our
environment.
3. INSTALLATION
DANGER
Ö Before you begin any work on this
product, make sure that:
- all electrical power to the unit has
been switched off
- and that the through-hull valves are in
the CLOSED or STOP position.
3.1 MOUNTING THE DEVICE
• Maxlite+S can be installed in place of a toilet with a
manual pump.
• Mount the Maxlite+S securely using the screws
provided. Your mountings must be appropriate for the
base on which the device is to be installed.
Note: You can turn Maxlite+S bowl to suit your
requirements and the space available (see installation
instructions).
• Observe the pumping direction (arrows) when turning
the unit over.
• Preparing to mount the rocker switch: cut out a
1" rectangular panel.
3.2 CONNECTING THE DISCHARGE
IMPORTANT
Pollution risk.
Ö All boats built from 2008 onwards must be
equipped with a black water recovery tank.
Favour the emptying of black water tanks thanks
to the installations provided in the ports.
Ö Please check local legislation regarding discharge
from on board toilets- i.e. holding tanks etc.
A seacock should be fitted where the Sanimarin® Maxlite+S
discharges through a skin fitting.
DANGER
Ö For units installed below the water line, the
discharge pipe should rise at least 20 inches above
water level and be fitted with an anti-syphon valve
prior to falling and discharging through the skin
fitting.
The device outlet is fitted with a non-return valve.
The outlet diameter is 1-1/2" (if necessary an adapter for
1" is provided in the accessory bag).
3.3 CONNECTING THE WATER SUPPLY
• Connect Maxlite+S to the on-board pressurized water
system using the supplied 3/4"-3/4" solenoid valve.
12
Component materials
Bowl
Copolyester
Base
Polyamide
x
1-1/2"

Publicidad

loading

Este manual también es adecuado para:

Saniflo serieSanimarin maxlite+s