'\ b/
WARNING
A moving grage door can cause serious injury or death.
Keepthe path clear.
Position the ladder to the side of the Power Head so it is
clear of all moving parts of the Opener and the door.
Set the door Opener to use the minimum force needed
to open the door.
........
ki17.......
B
OPEN ADJUSTMENT
On front panel of Power Head find adjusting
screw
marked "OPEN" (Figure 9).
Gently turn screw counterclockwise
until it stops.
-
Very little force is required to turn adjusting
screw.
Press Wall Console to close garage door.
-
Observe if door stops at"OPEN" limit switch.
If door is fully open--adjustment
is finished.
-
If door stops but is not fuly open,
a.
Measure distance between
bottom
of door
top of door opening.
b.
Move "OPEN" Limit Switch that same distance
toward Power Head.
-
If door stops before reaching the"OPEN" Limit Switch
a.
Slightly increase OPEN Force setting (clockwise).
-
If door fails to move, see Troubleshooting
Section,
pages 15.
C
Run Door Opener
Cycle opener a few times to double check settings.
Repeat adjustment
steps as necessary.
........
ki17...
SITTIH6
<CI _U'_+{°"__
= Jl.= &_=
I,_IVIB,sI
I<iIIHCTlOH
NOTE
Limit Switch and Force Adjustments must be completed
before checking the contact reverse function (Figure 10
).
A
Open garage door using Wall Console.
B
Lay a 2" x 4" board flat in center of doorway.
C
Close door using Wall Console.
D
Check that door stops and reverses within
2 seconds after it
contacts board:
If door does not reverse, decrease Close Force until
door reverses.
If door still does not reverse, move Limit Switch
toward door.
E
Check Safe-T-Beam ® System operation:
If beam is blocked, door will not close.
NOTE
The door must contact the 2" x 4" board before the Carriageactivates
the Close Limit Switch. If not, readjust the Close Limit Switch.
2" x 4" board
laid flat
Figure 10 Checking Contact
Reverse