Descargar Imprimir esta página

Mottura 1805M28 Manual De Instrucciones, Uso Y Mantenimiento página 10

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
FAULT
The system does not move
The system does not stop
at the correct position
Voltage: 24 VDC
Current: 0,4 A
Power: 9,6 W
Torque: 0,7 Nm
Revolutions: 34 RPM
Limit switch capacity: 39 turns
Diameter: 25 mm
Protection level: IP44
Weight: 0,32 Kg
Length of power lead: 3 m 
8
Troubleshooting
POSSIBLE CAUSE
Limit stops incorrectly set
Incorrect wiring
No electrical power
Faulty motor unit.
Limit stops incorrectly set
Obstructions in the curtain
work space
Technical Characteristics
4
REMEDY
Set the limit stops
Check and correct the wiring by following
the instructions in this manual
Restore electrical power
Request replacement of the motor unit.
Set the limit stops
Remove obstructions

Publicidad

loading