You will find the illustrations referred to above in the pages 3 – 5 of these
instructions for use.
Scope of delivery
Tank [1], with pump [2] and spare parts pouch [3], spray line [4], instructions for use [5],
carrying strap [6], spray lance [7], pump holder [8]. (Figs 1a and 1b)
Technical data
Device family
Type
Max. filling amount
Total contents
Max. spraying pressure
Max. operating temperature
Weight when empty
Total weight max. approx.
Material of tank
Where device is carried
Technical residual quantity
Max. volume flow
Recoil force
Table 1
Assembly
1. Fasten the carrying strap(s) [6] on the tank [1]. (Figs. 2a + 2b)
2. Screw the spray line [4] tightly into the outlet port [10]. (Fig. 3).
+
Note the location of the spigot in order to be able to insert the lock.
3. Insert the lock [11]. (Fig. 3).
► The lock closes and the spray line is secured from unscrewing out of the tank.
4. Push the hose [4] onto the shut-off valve [9] and secure it with the cap nut. (Fig. 3)
5. Screw the spray lance [7] onto the shut-off valve [9] (Fig. 3).
Checks
Visual inspection: Are the tank [1], pump [2], spray line [4] with shut-off valve [9], pressu-
re gage [16] and spray lance [7] undamaged? (Figs. 1, 11)
+
Pay special attention to the connections between the tank – spray line and the spray line
– shut-off valve and to the condition of the pump threading and spray line.
Pump up the empty device to 2 bar.
No leaks:
► The pressure must not decrease more than 0.5 bar within 30 minutes.
Function:
Pull the red button on the safety valve [12]. (Fig. 4).
► The pressure must dissipate.
+
Using the wheel lock [40] the lever on the shut-off valve [9] can be locked and unlo-
cked. Unintentional spraying is prevented after locking. (Fig. 15)
► If required, reset the wheel lock [40] and activate the shut-off valve [9]. (Fig. 15)
► The shut-off valve must open and close.
Have damaged parts or parts that do not work properly repaired immediately by our
customer service department or by service partners authorized by us.
FERROX PLUS
3565P
3585P
6 l
9 l
4.7 kg
5.2 kg
11 kg
Steel with polyester coating
Shoulder
15
3595P
10 l
6 l
13 l
9 l
6 bar (88 psi)
50 °C (130 °F)
4.2 kg
15 kg
10 kg
Stainless steel
Back
Shoulder
0.03 l
0.78 l/min
< 5 N
ENGLISH
INOX PLUS
3615P
10 l
13 l
4.7 kg
15 kg
Back

Publicidad