To remove the selected parameter or function from the
Welding Parameters Bar [44]:
Access to the User Setup.
Use the Right Knob [36] to highlight the parameter or
function icon which is added to the Welding
Parameters Bar [44].
Figure 15.
Press the Right Knob [36] – The selected icon will
disappear from the display bottom.
Figure 16.
The
Selected
parameters
disappeared from the Welding Parameters Bar [44]
Figure 17.
English
or
function
was
16
Preflow Time adjusts the time that shielding
t1
gas flows after the trigger is pulled and prior
to feeding.
Adjust range: from 0 seconds (OFF) to 25 seconds
(factory default is set at Auto mode).
Postflow
Time
shielding gas flows after the welding output
t2
turns off.
Adjust range: from 0 seconds (OFF) to 25 seconds
(factory default is set at Auto mode).
Burnback Time is the amount of time that
the weld output continues after the wire
stops feeding. It prevents the wire from
sticking in the puddle and prepares the end of the wire
for the next arc start.
Adjust range: from OFF to 0.25 seconds (factory
default is set at Auto mode).
Spot Timer– adjusts the time welding will
continue even if the trigger is still pulled.
This option has no effect in 4-Step Trigger
Mode.
Adjust range: from 0 second (OFF) to 120 seconds
(factory default is OFF).
WARNING
Spot Timer has no effect in 4-Step Trigger Mode.
Run-in WFS – sets the wire feed speed
from the time the trigger is pulled until an arc
is established.
Adjust range: from minimum to maximum WFS
(factory default is set at Auto mode).
The Start Procedure – controls the WFS
and Volts (or Trim) for a specified time at the
beginning of the weld. During the start time,
the machine will ramp up or down from the Start
Procedure to the preset Welding Procedure.
Adjust time range: from 0 seconds (OFF) to
10 seconds.
Crater Procedure – controls the WFS (or
value in ampere units) and Volts (or Trim) for
a specified time at the end of the weld after
the trigger is released. During the Crater time, the
machine will ramp up or down from the Weld Procedure
to the Crater Procedure.
Adjust time range: from 0 seconds (OFF) to
10 seconds.
A/B procedure – enables quick weld
A/B
procedure change. The sequence changes
may occur between:
Two different welding programs.
Different settings for the same program.
adjusts the time that
English

Publicidad

loading