Positioning the Generator for Operation
DANGER
Carbon monoxide. Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide (CO). This is a poison you cannot
see or smell. If you can smell the generator exhaust, you are breathing CO. But
even if you cannot smell the exhaust, you could be breathing CO.
► Do not operate this generator unless it is properly positioned. Read and obey all
instructions provided below.
WARNING
Risk of electric shock or electrocution.
► Do not operate this generator in rain, snow, or standing water.
Requirements Position the generator according to the following requirements.
Do not operate the generator anywhere inside a home or building. This includes
the garage (c), entryway, porch, or sunroom (d), living area or work space (e), or
basement or crawl space (f). Operating the generator inside a home or building
can be fatal even if fans, open doors, or open windows are used for ventilation.
ONLY use a generator outside (a), and far away from homes, buildings,
windows, doors, and vents. Windows, doors, and vents can pull in generator
exhaust.
Point the engine exhaust (b) away from homes, buildings, windows, doors, and
vents. Also, point the engine exhaust away from combustible materials.
Position the generator on firm, level ground so that it will not slide or shift.