GENERAL PRECAUTIONS
La NORDICA S.p.A. responsibility is limited to the supply of the appliance.
THE INSTALLATION MUST BE CARRIED OUT SCRUPULOUSLY ACCORDING TO THE INSTRUCTIONS PROVIDED IN THIS MANUAL AND THE
RULES OF THE PROFESSION. INSTALLATION MUST ONLY BE CARRIED OUT BY A QUALIFIED TECHNICIAN WHO WORKS ON BEHALF OF
COMPANIES SUITABLE TO ASSUME THE ENTIRE RESPONSIBILITY OF THE SYSTEM AS A WHOLE.
LA NORDICA S.P.A. DECLINES ANy RESPONSIbILITy fOR ThE PRODUCT ThAT hAS bEEN mODIfIED wIThOUT
wRITTEN AUThORISATION AS wELL AS fOR ThE USE Of NON-ORIGINAL SPARE PARTS. NO mODIfICATIONS CAN bE
CARRIED OUT TO ThE APPLIANCE. LA NORDICA S.P.A. CANNOT bE hELD RESPONSIbLE fOR LACk Of RESPECT fOR
SUCh PRECAUTIONS.
THIS APPLIANCE IS NOT SUITABLE FOR THE USE OF INEXPERIENCED PEOPLE INCLUDED CHILDREN OR WITH PHYSICAL, SENSORIAL AND
MENTAL REDUCED CAPACITIES. THEY HAVE TO BE CONTROLLED AND EDUCATED IN THE USE OF THE APPLIANCE FROM A RESPONSIBLE
PERSON FOR THEIR SECURITY. THE CHILDREN HAVE TO BE CONTROLLED TO BE SURE THAT THEY WOULD NOT PLAY WITH THE APPLIANCE.
EN 60335 2 102/7.12 .
IT IS ObLIGATORy TO RESPECT ThE NATIONAL AND EUROPEAN RULES, LOCAL REGULATIONS CONCERNING bUILDING mATTER
AND ALSO fIREPROOf RULES.
DECLARATION Of CONfORmITy Of ThE mANUfACTURER
OBJECT: AbSENCE Of ASbESTOS AND CADmIUm
WE DECLARE THAT THE MATERIALS USED FOR THE ASSEMBLY OF ALL OUR APPLIANCES ARE WITHOUT ASBESTOS PARTS OR ASBESTOS
DERIVATES AND THAT IN THE MATERIAL USED FOR WELDING, CADMIUM IS NOT PRESENT, AS PRESCRIBED IN RELEVANT NORM.
OBJECT: CE N. 1935/2004 REGULATION.
WE DECLARE THAT IN ALL PRODUCTS WE PRODUCE, THE MATERIALS WHICH WILL GET IN TOUCH WITH FOOD ARE SUITABLE FOR
ALIMENTARY USE, ACCORDING TO THE A.M. CE REGULATION.
INSTALLATION REGULATIONS
INSTALLATION OF THE PRODUCT AND AUXILIARY EQUIPMENT IN RELATION TO THE HEATING SYSTEM MUST COMPLY WITH ALL CURRENT
STANDARDS AND REGULATIONS AND TO THOSE ENVISIONED BY THE LAW.
THE INSTALLATION AND THE RELATING TO THE CONNECTIONS OF THE SYSTEM, THE COMMISSIONING AND THE CHECK OF THE CORRECT
FUNCTIONING MUST BE CARRIED OUT IN COMPLIANCE WITH THE REGULATIONS IN FORCE BY AUTHORISED PROFESSIONAL PERSONNEL
WITH THE REQUISITES REQUIRED BY THE LAW, BEING NATIONAL, REGIONAL, PROVINCIAL OR TOWN COUNCIL PRESENT IN THE COUNTRY
WITHIN WHICH THE APPLIANCE IS INSTALLED, BESIDES THESE PRESENT INSTRUCTIONS.
INSTALLATION MUST BE CARRIED OUT BY AUTHORISED PERSONNEL WHO MUST PROVIDE THE BUYER WITH A SYSTEM DECLARATION OF
CONFORMITY AND WILL ASSUME FULL RESPONSIBILITY FOR FINAL INSTALLATION AND AS A CONSEQUENCE THE CORRECT FUNCTIONING
OF THE INSTALLED PRODUCT.
BEFORE INSTALLING THE APPLIANCE, CARRY OUT THE FOLLOWING CHECKS:
• Verify if your structure can support the weight of the appliance. In case of insufficient carrying capacity it is necessary to
adopt appropriate measures, La NORDICA responsibility is limited to the supply of the appliance (See chapter TECHNICAL
DESCRIPTION).
• Make sure that the floor can support the weight of the appliance, and if it is made of flammable material, provide suitable
insulation (DIMENSIONS ACCORDING TO REGIONAL REGULATIONS).
• Make sure that there is adequate ventilation in the room where the appliance is to be installed, with particular attention to windows and
doors with tight closing (seal ropes).
• DO NOT INSTALL THE APPLIANCE IN ROOMS CONTAINING COLLECTIVE VENTILATION DUCTS, HOODS WITH OR WITHOUT EXTRACTOR,
TYPE B GAS APPLIANCES, HEAT PUMPS, OR OTHER APPLIANCES THAT, OPERATING AT THE SAME TIME, CAN PUT THE ROOM IN
DEPRESSION REF. UNI 10683 STANDARD
• Make sure that the ue and the pipes to which the appliance will be connected are suitable for its operation. IT IS NOT ALLOwED ThE
CONNECTION Of vARIOUS APPLIANCES TO ThE SAmE ChImNEy.
• The diameter of the opening for connection to the chimney must at least correspond to the diameter of the ue gas pipe. The opening
must be equipped with a wall connection for the insertion of the exhaust pipe and a rosette.
• The unused ue gas exhaust stub pipe must be covered with its respective cap (see chapter DIMENISIONS).
• The installation must be appropriate and has to allow the cleaning and maintenance of the product and the ue.
BEFORE INSTALLATION, ACCURATELY WASH THE PIPES OF THE SYSTEM IN ORDER TO REMOVE ANY RESIDUALS THAT COULD COMPROMISE
THE CORRECT FUNCTIONING OF THE APPLIANCE.
ImPORTANT:
A IT WOULD BE APPROPRIATE TO INSTALL AN AUTOMATIC OR MANUAL AIR VALVE TO ALLOW THE AIR OUTLET FROM THE PLUMBING
SYSTEM;
B IN CASE OF WATER LEAKING, CLOSE THE WATER SUPPLY AND PROMPTLY WARN THE AFTER SALES TECHNICAL SERVICE;
C THE SYSTEM WORKING PRESSURE MUST PERIODICALLY BE CHECKED.
D IF NOT USING THE BOILER FOR A LONG PERIOD OF TIME, IT IS RECOMMENDED THAT THE AFTER SALES TECHNICAL SERVICE IS
CONTACTED TO CARRY OUT AT LEAST THE FOLLOWING OPERATIONS: CLOSE THE WATER TAPS OF BOTH THE THERMAL SYSTEM AND
THE DOMESTIC HOT WATER SYSTEM; EMPTY THE THERMAL SYSTEM AND THE DOMESTIC HOT WATER SYSTEM IF THERE IS RISK OF
FREEZING.