Descargar Imprimir esta página

Johnson Pump SPXFLOW 500 GPH Manual De Instrucciones página 14

Ocultar thumbs Ver también para SPXFLOW 500 GPH:

Publicidad

EN
TO REMOVE LEGACY
MOTOR CARTRIDGE
See page 19
1. Lift tab and rotate the two fins
in a counter clockwise
direction and lift out.
2. To reinstall, first make sure
that the o-ring seal is properly
located. Coat the o-ring seal
with Food Grade Synthetic
Grease (NSF H1), then align
the two cams on either
side of the motor cartridge
with the two slots in the outer
housing. Press down and
twist in a clockwise rotation.
To ensure that the power
cartridge is properly located,
twist fins in a counter
clock-wise direction without
lifting tab. Cartridge should
stay in place.