Accesorios de comunicación vía gsm/gprs

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
Ingeteam
The aerial connectors and their connection terminals are those listed below.
The connector J3 is dedicated to the RS-485 bus for the connection of a local PC.
The connector J4 allows the unit to be connected to an RS-485 bus with the aim of establishing
communication with other nearby units via cables.
Pin
1
2
3
4
* Terminal to facilitate the connection.
The jumper JP2 enables the connection of the end of line resistor in the RS-485 bus.
The jumper JP2 must be closed in the two units considered as end of line of the RS-485 bus.
Consult the accessories manual for communication via RS-485 for more information on the RS-485
wiring.
For the correct synchronisation of the modem the inverter 01 must be in the RS-485 bus.
Configuration of the modem in the INGECON SUN Manager
Access the INGECON SUN Manager software and follow the guidelines indicated to configure the modem.
1.
Connect with the plant where the modem is located (consult section "5.1. Communication via GPRS" for
information on connecting the remote PC).
2.
Right-click on the plant selected and click on Modem Configuration.
3.
Click on Read.
4.
Configure the necessary parameters.
A brief description of the parameters to configure shows below.
Alarms
The alarms warn of incidents in the installation at the moment they occur.
Parameter
Inverters
Test message
Minutes with alarm in Inverter
Minutes with alarm in Tracker
Grid connections
26
Signal
RS-485 B (+)
RS-485 A (-)
Protection shield*
GND
Number of inverters forming the plant.
Option for the modem to send a test message to telephone 1. This verifies it is working correctly.
Minimum duration in minutes that an alarm is required in the inverter for a message to be sent
from the modem.
Minimum duration in minutes that an alarm is required in the tracker for a message to be sent
from the modem.
Number of network connections in one day that is considered a network connection problem. An
alarm message is generated.