Descargar Imprimir esta página

Bosch 0601063L00 Manual Original página 28

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
28 | English
Operation
Starting Operation
Protect the measuring tool from moisture and direct sunlight.
u
Do not expose the measuring tool to any extreme temperatures or fluctuations in
u
temperature. For example, do not leave it in a car for extended periods of time. If it
has been subjected to significant fluctuations in temperature, first allow the measur-
ing tool to adjust to the ambient temperature and then always carry out an accuracy
check before continuing work (see "Accuracy Check of the Measuring Tool",
page 30).
The precision of the measuring tool may be compromised if exposed to extreme tem-
peratures or fluctuations in temperature.
Avoid substantial knocks to the measuring tool and avoid dropping it. Always
u
carry out an accuracy check before continuing work if the measuring tool has been
subjected to severe external influences (see "Accuracy Check of the Measuring Tool",
page 30).
Switch the measuring tool off when transporting it. The pendulum unit is locked
u
when the tool is switched off, as it can otherwise be damaged by big movements.
Switching On/Off
To switch on the measuring tool, slide the on/off switch (2) to the "  On" position (for
working with the pendulum lock) or to the "
levelling). The status indicator (7) lights up. As soon as it is switched on, the measuring
tool emits laser lines from the outlet apertures (1).
Do not direct the laser beam at persons or animals and do not stare into the laser
u
beam yourself (even from a distance).
To switch off the measuring tool, slide the on/off switch (2) to the "Off" position. The
status indicator (7) goes out. The pendulum unit is locked when the tool is switched off.
Never leave the measuring tool unattended when switched on, and ensure the
u
measuring tool is switched off after use. Others may be blinded by the laser beam.
If the maximum permitted operating temperature of 50 °C is exceeded, the tool shuts
down to protect the laser diode. Once it has cooled down, the measuring tool is opera-
tional again and can be switched back on.
Automatic shut-off
If no button on the measuring tool is pressed for approx. 120 min, the measuring tool will
automatically switch itself off to preserve battery life.
1 609 92A 7LU | (29.04.2022)
 On" position (for working with automatic
Bosch Power Tools

Publicidad

loading

Este manual también es adecuado para:

Gll 2-10 professional