Descargar Imprimir esta página

SICK WTF4S 20 Serie Instrucciones De Uso página 35

Fotocélula miniatura

Publicidad

6.5
Configuration via IO-Link
7
Troubleshooting
8028214/2023/10/20 | SICK
Subject to change without notice
NOTE
After teach-in, approx. 1/3 of the linear light spot must be covered for the sensor
to switch. The sensitivity can be adjusted by turning so that the sensor also
switches with less coverage.
The sensor is adjusted and ready for operation.
WTF4S-xxxxxx3x
Adjustment via teach-in: The sensing range is adjusted by pressing the teach-in button
(approx. 1-3 sec.).
NOTE
Do not operate the teach-in button using sharp objects.
WTF4S-xxxxxxAx
Sensor with fixed sensing range and no adjustment.
NOTE
Configuration via BluePilot is shown in the following tutorial:
In addition to manual setting the parameters on the device, the sensor can also be
configured via IO-Link.
Configuration via IO-Link can be performed in two ways:
Configuration via the SiLink box (required software: SOPAS ET from SICK)
To do this, connect the sensor to a computer via USB using the SiLink box.
Configuration via an IO-Link Master (PLC), e.g. SIG350
You can quickly and easily test and parameterize the connected products using the
SOPAS ET program (SICK Engineering Tool with graphic user navigation and convenient
visualization).
Details on configuration can be found in the detailed IO-Link description:
Information: Photoelectric sensors, SICK Smart Sensors /
The Troubleshooting table indicates measures to be taken if the sensor stops working.
OPERATING INSTRUCTIONS
Technical
IO-Link.
O P E R A T I N G I N S T R U C T I O N S | WTF4S
en
35

Publicidad

loading

Este manual también es adecuado para:

Wtf4s 30 serieWtf4s 10 serieWtf4s a0 serie