UVP wake-up function
Some Lithium batteries incorporate a UVP protection (Under Voltage Protection) which disconnects the battery in
case of deep discharge. This protection prevents the charger from detecting the battery. To enable the Gysflash
8.48 PL-E to charge the battery, the UVP protection must be deactivated. To do this, activate the UVP Wake-up
function on the charger. Once activated, this function will run a battery wake-up procedure every 5 minutes.
Procedure for activating or deactivating the UVP wake-up function:
1. Enter one of the Lithium charging modes.
2. Unplug the product from the mains and wait until the charger switches off.
3. Keep the
button pressed while connecting the mains plug.
• If the Li-ion, LiFePO4 and
• If the Li-ion, LiFePO4 and
4. Unplug the mains plug until the charger switches off. The settings will be saved.
Tip for checking whether the UVP wake-up function is active:
• Restart the product.
• If all the LEDs light up at the same time for one second, the UVP wake-up function has been activated.
• If the LEDs illuminate one after the other, the UVP wake-up function is deactivated.
In the case of UVP protection on a lithium battery, it is recommended that all the consumers on the
battery are removed so that the UVP wake-up function works correctly.
• Lead-acid charge curve:
The Gysflash 8.48 PL-E features an advanced 6 (or 7) stage charging curve that optimizes battery performance.
This automatic charge curve is adapted to all types of lead-acid batteries (liquid/GEL and AGM) to ensure the optimal
charge level for the battery. This curve is fully compatible even when there are consumers present on the battery.
1
U
I
Analyse
Récupération
<1s
Max 8h
défaut après
1
Step
: Analysis
Analysis of the battery status (level of charge, reverse
polarity, incorrect battery connected...)
2
Step
: Recovery (3 A)
Recovering damaged elements following a prolonged
deep discharge.
3
Step
: Desulphation (62 V)
Battery desulphation process.
4
Step
: Charge (8 A)
Fast charge at maximum current to reach 80% charge
level.
Liquid/Gel
AGM
Liquid/Gel-Traction
57.2 V
58.8 V
Translation of the original
instructions
LEDs are lit, the UVP wake-up function is active.
LEDs are lit, the UVP wake-up function is deactivated.
2
Désulfatation
Max 12h
défaut après
AGM-Traction
57.6 V
58.8 V
4
5
Charge
Absorption
2h - 4h
5
Step
: Absorption
Constant voltage charging to bring the charge level up to 100%.
Liquid/Gel
AGM
Liquid/Gel-Traction
57.2 V
58.8 V
6
Step
: Traction (62 V)
If the traction option has been selected, the charger will apply an ad-
ditional current to create gas, which will mix the electrolyte and re-
condition the battery cells. During this phase, the battery may lose
some water.
7
Step
: Maintenance charge (54 V)
Battery charge level maintained at maximum.
GYSFLASH 8.48 PL-E
6
7
Traction
Maintien de
charge
Si option activée
1h - 4h
No limit
AGM-Traction
57.6 V
58.8 V
9

Publicidad