Grease filters
The mesh filters can be cleaned by hand. Soak them for about 3 minutes in water with a mild
detergent and then brush them gently with a soft brush. Do not exert too much pressure to
avoid damaging it. (Leave to dry in the open air, away from direct sunlight). Fig. 15
Filters should be washed separately from the dishes and other cooking utensils. It is
advisable not to use rinse aid.
5. TROUBLESHOOTING
Problem
The light is on, but
the engine does not
work
The light and the
motor are not
working
Oil leakage
Cause
Fan switch off
Fan switch failure
Damaged motor
House fuses are burnt out
Power cable is loose or
disconnected
One-way valve and outlet are
not hermetically sealed
Leakage at chimney and cover
connection
Solution
Select a fan switch position.
Contact the official Cecotec
Technical Support Service.
Contact the official Cecotec
Technical Support Service.
Reset/replace fuses.
Reconnect the power cord to the
power outlet.
Connect the product to the mains
socket.
Remove the one-way valve and
seal it with sealant.
Disassemble the chimney and seal
it.