2. Identify the type of circuit.
In a Single Pole Circuit (see Fig. 2), two single wires
connect to two screws on the existing switch. A ground
wire may also be present and connected to a ground
terminal on the old switch.
For your safety: Connecting a proper ground to the
sensor provides protection against electrical shock
in the event of certain fault conditions. If a proper
ground is not available, consult with a qualified
electrician before continuing installation.
Only connect the RW600B to a Single Pole Circuit. The
RW600B is not suitable for 3-way switching. If the existing wiring does not match the
description for a Single Pole Circuit, you should consult with a qualified electrician.
3. Prepare the Wires.
Tag the wires currently connected to the existing switch, so
that they can be identified later. Disconnect the wires. Make
sure the insulation is stripped off the wires to expose their
copper cores to the length indicated by the "Strip Gage,"
in Fig. 3 (approximately 1/2 inch).
4. Wire the sensor.
Twist the existing wires together
with the wire leads on the RW600B
sensor as indicated below. Cap them
securely using the wire nuts provided.
See Fig 4.
• Connect the power wire (HOT) from
the circuit to the black wire on the
RW600B.
• Connect the green or non-insulated
(copper) GROUND wire from the
circuit to the green ground wire on
the RW600B. Make sure there is a
solid ground connection.
• If neutral is available in the box,
connect to the Blue and White striped
(signal) wire on the RW600B. In cases
of retrofit or replacement where no
neutral is present, connect the signal wire to ground.
• Connect the power wire to the lamp or fan (LOAD) to the red wire on the RW600B.
5. Put the RW600B in the wall box.
Position the lens above the ON/OFF button (lens at top, button at bottom). Secure it
to the wall box with the screws provided.
6. Make any necessary adjustments.
information.
7. Attach the new cover plate.
8. Restore power to the circuit.
INITIAL POWER UP DELAY
There is an initial warm-up and calibration period the first time power is applied to the
unit after a power failure lasting more than 5 minutes, and after the load is replaced.
SENSOR ADJUSTMENT & PROGRAMMING
To adjust the RW600B, use controls located under the front
cover (lens and ON/OFF button). The wall switch wallplate
must be removed to gain access to the adjustment dial
under the ON/OFF button.
1. Remove the wallplate.
2. Firmly grasp the edges of the front cover
directly below the lens where it says "open"
(see Fig. 5). Push in one side first until it
pops out, then the other side. Remove front
cover from the unit.
Adjusting the Time Delay
The factory setting for the time delay dial is fully clockwise,
providing the maximum delay of 30 minutes. To reduce the
amount of time the load remains ON after the last motion
detection, turn the dial counterclockwise (minimum = 30
seconds). You can set the following times: 30 minutes, 20
minutes, 10 minutes, 5 minutes, 30 seconds.
Do not overturn the time delay adjustment dial.
Status LED
Push and hold the ON/Off push button twelve seconds to enable
and disable the Status LED indicator light on the ON/OFF button.
The factory default setting is enabled. When enabled,
the Status LED blinks when the sensor detects motion, whether
the load is ON or OFF.
CAUTION
Turn on the breaker or replace the fuse.
CAUTION
Call 800.223.4185 for Technical Support
Black -> HOT (power
Fig 4: Sensor orientation, wire connections
and wall box assembly
See the SENSOR ADJUSTMENT section for
HOT (power from
circuit box)
Ground
Fig 2: Typical Single Pole
Switch Wiring
Fig 3: Wire Stripping
from circuit box)
Red -> LOAD (power
to lamp or fan)
T im
M ot
e
io n
D e la
O F F
B lin
30 m
y
k
in .
20 m
30 se
in .
c.
5m
10 m
in .
in .
Blue with White Stripe
(Signal Wire) – NEUTRAL
NOTE: In cases of retro t or replacement where
no neutral is present, connect signal wire to ground.
Fig 5: Remove Front Cover
Fig 6: Time Delay
Adjustment
NEUTRAL
LOAD
(power
to lamp)
Strip Gage
1/2"
12.7mm
Green -> GROUND
T im
e
D e la
y
3 0 m
in .
2 0 m
in .
3 0 se
c.
5 m
1 0 m
in .
in .

Publicidad

loading