CHANGING THE COLOR OF THE UNIT
1. Remove the wallplate
2. Firmly grasp the edges of the front cover directly below
the lens where it says "open." Push in one side first
until it pops out, then the other side. Remove
front cover from the unit (see Fig. 5).
3. Take the new color front cover, place the top
peg in first then snap in each side one at a
time (see Fig. 7).
TROUBL ESHOOTING
Status LED is enabled but not blinking and the load will not turn ON:
• Check the circuit breaker to be sure it is functioning.
Load will not turn ON:
Press ON/OFF button. The load should turn ON. If not:
• Check the light bulb and/or motor switch on the fan mechanism.
• Turn off power to the circuit then check wire connections.
Load will not turn OFF:
Note: The time delay can be set from 30 seconds to 30 minutes. Ensure that the time
delay is set to the desired delay and that there is no movement within the sensor's view
for that time period.
• To quickly test the unit for proper operation, turn the time delay to minimum and
move out of the sensor's view. Lights should turn off after 30 seconds.
• Press the ON/OFF button. If load does not turn off, turn off power to the circuit then
check wire connections.
• If load still does not turn off call 800.223.4185 for technical support
WARRANTY INFORMATION
Pass & Seymour/Legrand warranties its products to be free of defects in materials
and workmanship for a period of five (5) years. There are no obligations or liabilities
on the part of Pass & Seymour/Legrand for consequential damages arising out of, or
in connection with, the use or performance of this product or other indirect damages
with respect to loss of property, revenue or profit, or cost of removal, installation or
reinstallation.
P.O. Box 4822, Syracuse, NY 13221-4822
Made in China. Part No. 341343 08/20
SPÉCIFICATIONS
Tension .................................................................................120 VCA, 60 Hz
Charge (circuit unipolaire)
Lampe incandescente ou fluorescente .............................. 0-600 watts
Moteur de ventilateur ................................................................... 1/6 hp
Délai ...................................................................30 secondes à 30 minutes
Environnement .............. Utilisation résidentielle à l'intérieur uniquement
Température de fonctionnement ........................ 0 à 55 °C (32 à 131 °F)
Humidité ...................................................95 % HR, sans condensation
Outils nécessaires
Tournevis isolé
Pince à dénuder
Technical Support: 800.223.4185
www.legrand.us
Lire toutes les instructions avant l'installation.
Interrupteur à détecteur
Lentille
Bouton MARCHE/ARRÊT
avec DEL de détection
de mouvement
Fig 7: Replace Front Cover
RW600B
de présence
T im
e
D e la
y
3 0 m
in .
2 0 m
in .
3 0 se
c.
5 m
1 0 m
in .
in .
Please
Recycle