Descargar Imprimir esta página

SunPower Maxeon 3 SPR-MAX3-COM Serie Instrucciones De Seguridad E Instalación página 12

Módulos fotovoltaicos

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 87
Maxeon 3 112 cells AC Ready Solar Panel
(SPR-MAX3-XXX-R, SPR-MAX3-XXX-BLK-R, SPR-MAX3-XXX-COM-R)
0
50
150
272
TOP CLAMPS
Moun ng
Moun ng Configura on Diagram
Configura on
Descrip on
Front View
Back View
Long Side Moun ng,
Rails Perpendincular
to Moun ng Frame
Long Side Moun ng,
Rails Perpendincular
to Moun ng Frame
Long Side Moun ng,
Point Supported
Long Side Moun ng,
Rails Parallel to
Moun ng Frame
Short Side Moun ng,
Rails Perpendicular to
Moun ng Frame
(End Mount)
Short Side Moun ng,
Point Supported
(End Mount)
Short Side Moun ng,
Rails Parallel to
Moun ng Frame
(End Mount)
1 In the cases where hybrid moun ng is necessary (combina on of long and short side moun ng), the lowest
design load values should be considered as allowable design load.
2 Test loads are for informa on purposes only, design loads should be considered for the project design.
3 Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
par es, unless there is a formal authoriza on by Maxeon.
4 Rails must not be under the junc on box.
©2024 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice.
Safety and Installation Instructions - Document 001-15497 Rev.AB
350
450
710
1100 mm
1300 mm
1656 mm
1812 mm
Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
A - Ground Holes (4X Ø4.2mm)
B - Moun ng Holes (8X Ø6.8mm)
Moun ng Zone
Test Load
Design Load
Loca ons
Downward/Upward
(distance from corner
Downward/Upward
in mm)
(Pa)
(Pa)
50 - 150
+2700/-2700
+1800/-1800
150 - 272
+3600/-3600
+2400/-2400
272 - 450
+5400/-5400
+3600/-3600
+5400/-5400
+3600/-3600
350 - 450
+3600/-2400
450 - 710
+2400/-1600
Outer Clamps:
272 - 453
+7400/-7400
+4933/-4933
Middle Clamps:
856 - 956
50 - 150
+2700/-2700
+1800/-1800
+2400/-2400
150 - 272
+3600/-3600
272 -
450
+5400/-4200
+3600/-2800
450 - 710
+3600/-2400
+2400/-1600
+1800/-1800
50 - 150
+2700/-2700
150 - 272
+3600/-3600
+2400/-2400
272 -
450
+5400/-4200
+3600/-2800
450 - 710
+3600/-2400
+2400/-1600
BOLTS
+2700/-2700
+1800/-1800
0 - 350
0 - 350
+2700/-2700
+1800/-1800
0 - 350
+2700/-2700
+1800/-1800
7 Bo om flange moun ng.
8 Range indicates the posi oning of the clamps and not the rail
9 Slight bending may occur due to weight of the module.
MAXEON SOLAR TECHNOLOGIES, LTD.
710
450
350
GEN 5.2 FRAME PROFILE
SIDE FRAME PROFILE
40 mm
32 mm
Moun ng
Moun ng Configura on Diagram
Configura on
Descrip on
Front View
Back View
Long Side Moun ng,
Rails Perpendincular
to Moun ng Frame
Long Side Moun ng,
Point Supported
0
272
150
50
B
A
END FRAME PROFILE
40 mm
24 mm
Moun ng Zone
Test Load
Design Load
Loca ons
Downward/Upward
Downward/Upward
(distance from corner
(Pa)
(Pa)
in mm)
1300mm Holes
+5400/-5400
+3600/-3600
1100mm Holes
+5400/-5400
+3600/-3600
1300mm Holes
+5400/-5400
+3600/-3600
+3600/-3600
1100mm Holes
+5400/-5400
EN

Publicidad

loading