SunPower Performance 5 & 6 Bifacial Solar Panel
(SPR-P5-XXX-UPP, SPR-P6-XXX-COM-M-BF)
0
50
TOP CLAMPS
Moun ng
Moun ng Configura on Diagram
Configura on
Front View
Descrip on
Back View
Long Side Moun ng,
Rails Perpedincular to
Moun ng Frame
Long Side Moun ng,
Point Supported
Long Side Moun ng,
Rails Parallel to
Moun ng Frame
Short Side Moun ng,
Point Supported
(End Mount)
Short Side Moun ng,
Point Supported
with Rail
(End Mount)
Short Side Moun ng,
Rails Parallel to
Moun ng Frame
(End Mount)
1 In the cases where hybrid moun ng is necessary (combina on of long and short side moun ng), the lowest
design values should be considered as allowable design load.
2
Test loads are for informa on purposes only, design loads should be considered for the project design.
3 Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
par es, unless there is a formal authoriza on by Maxeon.
©2024 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice.
Safety and Installation Instructions - Document 001-15497 Rev.AB
1232.77
546
646
1042
A
400 mm
1100 mm
1400 mm
2384 mm
Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
A - SLOT Holes (8X 14mm (L) x 9mm (W), R3.5mm)
B - Moun ng Holes (4X 10mm (L) x 7mm (W), R6.8mm)
C - Ground Holes (4X Ø 4.2mm)
Moun ng Zone
Test Load
Design Load
Loca ons
Downward/Upward
Downward/Upward
(distance from corner
(Pa)
(Pa)
in mm)
+2400/-1200
+1600/-800
50 - 546
546 - 646
+5400/-2400
+3600/-1600
646 - 1042
+2400/-2000
+1600/-1333
50 - 150
+1800/-1800
+1200/-1200
+2000/-1600
+3000/-2400
546 - 646
50 - 546
+5400/-1200
+3600/-800
546 - 646
+5400/-2400
+3600/-1600
0 - 323
+933/-933
+1400/-1400
0 - 323
+3600/-2400
+2400/-1600
0 - 223
+1400/-1400
+933/-933
223 - 323
+2400/-1200
+1600/-800
MAXEON SOLAR TECHNOLOGIES, LTD.
1088.77
646 546
1042
B
GEN 4.3 FRAME PROFILE
SIDE FRAME PROFILE
35 mm
BOLTS
Moun ng
Moun ng Configura on Diagram
Configura on
Descrip on
Front View
Back View
Long Side Moun ng,
Rails Perpedincular to
Moun ng Frame
Center Moun ng
(1x Portrait Tracker)
4 IEC validated.
5 Bo om flange moun ng.
6 Range indicates posi oning of the clamp and not the rails.
7 Minimum of 24mm in diameter washer size is required.
8 Slight bending may occur due to weight of the module.
0
50
C
END FRAME PROFILE
16 mm
Moun ng Zone
Test Load
Design Load
Loca ons
(distance from corner
Downward/Upward
Downward/Upward
(Pa)
(Pa)
in mm)
1400mm Holes
+5400/-2400
+3600/-1600
+5400/-2400
+3600/-1600
1100mm Holes
400mm Holes
+2400/-2000
+1600/-1333
400mm Holes
+1800/-1800
+1200/-1200
EN