SunPower Maxeon 7 Residen al Solar Panel
(SPR-MAX7-XXX-PT)
0
148
50
269
TOP CLAMPS
This module is designed for Portrait Moun ng due to shorter cable length.
Moun ng
Moun ng Configura on Diagram
Configura on
Descrip on
Front View
Back View
Long Side Moun ng,
Rails Perpendincular
to Moun ng Frame
Long Side Moun ng,
Point Supported
Short Side Moun ng,
Point Supported
(End Mount)
Short Side Moun ng,
Rails Parallel to
Moun ng Frame
(End Mount)
1 In the cases where hybrid moun ng is necessary (combina on of long and short side moun ng), the lowest
design load values should be considered as allowable design load.
2 Test loads are for informa on purposes only, design loads should be considered for the project design.
3 Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
par es, unless there is a formal authoriza on by Maxeon.
©2024 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice.
Safety and Installation Instructions - Document 001-15497 Rev.AB
447
701
1100 mm
1300 mm
1787mm
Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
A - Ground Holes (4X Ø4.2mm)
B - Moun ng Holes (8X Ø6.8mm)
Moun ng Zone
Test Load
Design Load
Loca ons
Downward/Upward
Downward/Upward
(distance from corner
(Pa)
(Pa)
in mm)
50 - 148
+2700/-2700
+1800/-1800
148 - 269
+2400/-2400
+3600/-3600
269 - 447
+5400/-4200
+3600/-2800
447 - 701
+3600/-2400
+2400/-1600
50 - 148
+2700/-2700
+1800/-1800
148 - 269
+3600/-3600
+2400/-2400
+5400/-4200
269 - 447
+3600/-2800
447 - 701
+3600/-2400
+2400/-1600
0 - 350
+2700/-2700
+1800/-1800
+2700/-2700
+1800/-1800
0 - 350
MAXEON SOLAR TECHNOLOGIES, LTD.
447
701
GEN 4.2 FRAME PROFILE
SIDE FRAME PROFILE
32 mm
BOLTS
Moun ng
Moun ng Configura on Diagram
Configura on
Descrip on
Front View
Back View
Long Side Moun ng,
Rails Perpendincular
to Moun ng Frame
Long Side Moun ng,
Point Supported
4 Rails must not be under the junc on box.
6 Bo om flange moun ng.
7 Slight bending may occur due to weight of the module.
0
148
269
50
B
A
END FRAME PROFILE
24 mm
Test Load
Design Load
Moun ng Holes
Downward/Upward
Downward/Upward
Loca ons
(Pa)
(Pa)
1300mm Holes
+5400/-5400
+3600/-3600
1100mm Holes
+5400/-5400
+3600/-3600
1300mm Holes
+5400/-5400
+3600/-3600
+3600/-3600
1100mm Holes
+5400/-5400
EN