SunPower Performance 3 UPP Solar Panel
(SPR-P3-XXX-UPP)
0
158
303
TOP CLAMPS
Moun ng
Moun ng Configura on Diagram
Configura on
Descrip on
Front View
Back View
Long Side Moun ng,
Rails Perpedincular to
Moun ng Frame
Long Side Moun ng,
Rails Parallel to
Moun ng Frame
Short Side Moun ng,
Rails Perpendicular
to Moun ng Frame
(End Mount)
Short Side Moun ng,
Point Supported
(End Mount)
Short Side Moun ng,
Rails Parallel to
Moun ng Frame
(End Mount)
1 In the cases where hybrid moun ng is necessary (combina on of long and short side moun ng), the lowest
design load values should be considered as allowable design load.
2
Test loads are for informa on purposes only, design loads should be considered for the project design.
3 Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
par es, unless there is a formal authoriza on by Maxeon.
©2024 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice.
Safety and Installation Instructions - Document 001-15497 Rev.AB
566
883
690
400 mm
700 mm
1058 mm
1300 mm
2066 mm
A - Ground Holes (4X Ø 4.2mm)
B - SLOT Holes (8X 14mm (L) x 9mm (W), R4.5mm)
C - Moun ng Holes (8X 10mm (L) x 7mm (W), R3.5mm)
Moun ng Zone
Test Load
Design Load
Loca ons
Downward/Upward
Downward/Upward
(distance from corner
(Pa)
(Pa)
in mm)
+3600/-2400
158 - 303
+2400/-1600
303 - 566
+5400/-2400
+3600/-1600
566 - 690
+2400/-1800
+1600/-1200
690 - 883
+2400/-1600
+1600/-1067
303 - 566
+5400/-2400
+3600/-1600
240 - 340
+5400/-1500
+3600/-1000
0 - 100
+1400/-1400
+933/-933
+2400/-2400
+1600/-1600
100 - 340
MAXEON SOLAR TECHNOLOGIES, LTD.
883
690
566
GEN 4.3 FRAME PROFILE
SIDE FRAME PROFILE
35 mm
BOLT
Moun ng
Moun ng Configura on Diagram
Configura on
Front View
Back View
Descrip on
Long Side Moun ng,
Rails Perpedincular to
Moun ng Frame
4 Range indicates posi oning of the clamp and not the rails
5 Bo om flange moun ng
6 Slight bending may occur due to weight of the module.
0
303
158
C
B
A
END FRAME PROFILE
35 mm
Moun ng Holes
Design Load
Test Load
Downward/Upward
Downward/Upward
Loca ons
(Pa)
(Pa)
+5400/-2400
1058mm Holes
+3600/-1600
1300mm Holes
+3600/-1600
+5400/-2400
400mm Holes
+2400/-2400
+1600/-1600