Specifications
1-1 General Specifications
Display Count : 6000 count
Overrange Display : "OL or "-OL"
Conversion Rate : 2 times / second
Dimensions (W x H x D) : 60 x 147 x 31.5 mm
Weight : 140 g
Power requirement :
LR44 Size Button Battery 1.5Vx 2
Battery Life :
50 hours for 60.00A & 300.0A range only.
Maximum Conductor Size : 22 diameter
LVD : EN61010-1, EN61010-2-030,EN61010-2-032
EMC : EN61326-1
Installation category : CAT.Ⅲ. 600V.
CAT.
Ⅰ
The circuits not connected to mains.
The circuits directly connected to
Ⅱ
Lowvoltage installation.
Ⅲ
The building installation.
The source of the Low-voltage
Ⅳ
installation.
1-2 Environmental Conditions
Indoor Use.
Maximum operating altitude : 2000m (6562ft)
Operating temperature :
0°C ~ 30°C, ≦80%RH
30°C ~ 40°C, ≦75%RH
40°C ~ 50°C, ≦45%RH
Storage temperature :
-20 to +60°C, 0 to 80% RH (no batteries).
Temperature coefficient :
0.2 x (Specified accuracy) / °C, < 20°C, > 26°C
Pollution Degree : 2
Shock vibration :
MIL-PRF-28800F for A class 2 Instrument
Drop Protection :
4 Feet Drop to hardwood on concrete Floor
Application field
6
EN