INSTALLATION INSTRUCTIONS ( CONTINUED )
Change Register Orientation
NOTE: If the meter is plumbed in any orientation other than bottom-up flow,
the register may need to be reoriented.
1.
Using a 3mm L-hex wrench, remove the (4) screws that hold register in
place
2.
Rotate the register to the desired orientation, making sure the O-ring is
fully seated (see Figure 3).
3.
Reattach the register using the (4) screws previously removed
(see Figure 3).
Figure 3
8
EN
O-ring
Position Lug (4)