Battery Installation And Battery Type Setting (Wet Or Gel/Agm) - Clarke FOCUS II Micro Rider Instrucciones De Uso

Ocultar thumbs Ver también para FOCUS II Micro Rider:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6/14

BATTERY INSTALLATION AND BATTERY TYPE SETTING (WET OR GEL/AGM)

Battery installation
1.
Open the recovery tank cover (20) and check that the recovery tank (19) is empty, otherwise empty it with the recovery water
drain hose (24).
2.
Close the cover (20).
3.
Carefully lift the recovery tank assembly (19).
4.
Install the batteries and connect them according to the diagram (38).
Battery type setting
Set the function electronic board of the machine and the battery charger according to the type of batteries installed (WET or GEL/
AGM) as shown below:
Turn the ignition key (58) to "I" and, in the very irst seconds of machine operation, detect the current setting by counting the
5.
number of lashes of the battery warning lights (62), as shown in the following table:
SETTING
DISPLAY (71)
1
2
6.
If the setting is to be changed, perform the following procedure.
7.
Turn off the machine by turning the ignition key (58) to "0".
8.
Press and hold the switches (63) and (65) at the same time, then turn the ignition key (58) to "I".
9.
Release the switches (63) and (65) within 5 seconds of starting the machine.
10. Within 3 seconds, press the switch (65) to go to the next setting (1 to 6 in sequence).
NOTE
When performing steps 9 and 10, the settings are shown on the display (71) according to the code in the above table.
NOTE
The battery charger must be set according to the type of batteries.
Battery charging
11. Charge the batteries (see the procedure in Maintenance chapter).
7/11
INSTRUCTIONS FOR USE
BATTERY WARNING LIGHT INDICATION (62)
4 lashes of the red warning light
4 lashes of the green warning light
9099236000 - FOCUS II Micro Rider
BATTERY TYPE
WET
GEL-AGM
ENGLISH
13

Publicidad

Tabla de contenido
loading

Tabla de contenido