Use; Battery Check/Setting On A New Machine - Clarke FOCUS II Micro Rider Instrucciones De Uso

Ocultar thumbs Ver también para FOCUS II Micro Rider:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH

USE

WARNING!
On some points of the machine there are some adhesive plates indicating:
DANGER
WARNING
CAUTION
CONSULTATION
While reading this Manual, the operator must pay particular attention to the symbols shown on the plates.
Do not cover these plates for any reason and immediately replace them if damaged.

BATTERY CHECK/SETTING ON A NEW MACHINE

WARNING!
The electric components of the machine can be seriously damaged if the batteries are either improperly installed
or connected. The batteries must be installed by qualiied personnel only. Set the function electronic board
according to the type of batteries installed (WET or GEL/AGM).
Check the batteries for damage before installation.
Disconnect the battery connector and the battery charger plug.
Handle the batteries with great care.
Install the battery terminal protection caps supplied with the machine.
The machine requires 4 6 V batteries, connected according to the diagram (38).
The machine can be supplied in one of the following modes:
Batteries (WET or GEL/AGM) already installed and ready to be used
1.
Open the cover (20) and check that the recovery tank (19) is empty, otherwise empty it with the drain hose (24).
2.
Close the cover (20).
3.
Carefully lift the recovery tank assembly (19) from left side.
4.
Check that the batteries are connected to the machine with the connector (9).
5.
Carefully lower the recovery tank assembly (19).
6.
Insert the ignition key (58) and turn it to "I". If the green warning light (62) turns on, the batteries are ready to be used. If the
yellow or red warning light turns on, the batteries must be charged (see the procedure in Maintenance chapter).
Without batteries
1.
Buy appropriate batteries (see Technical Data paragraph).
For battery choice and installation, visit a qualiied battery Retailer.
2.
Set the machine according to the type of batteries installed (WET or GEL/AGM) (see the following paragraph).
3.
Install the batteries (see the following paragraph).
4.
Charge the batteries.
12
INSTRUCTIONS FOR USE
FOCUS II Micro Rider - 9099236000
7/11

Publicidad

Tabla de contenido
loading

Tabla de contenido